pRE-INSTALLATION INFORMATION

KHLDV Series Gas Fireplace

pRE-INSTALLATION INFORMATION

 

 

Fireplace Location

Plan for the installation of your appliance. This includes determining where the unit is to be installed, the vent configuration to be used, framing and finishing details, and whether any optional accessories (i.e. blower, wall switch, or remote control) are desired. Consult your local building code agency to ensure compliance with local codes, including permits and inspections.

The following factors should be taken into consideration:

Clearance to side-wall, ceiling, woodwork, and windows. Minimum clearances to combustibles must be maintained.

This fireplace may be installed along a wall, across a corner, or use an exterior chase. Refer to Figure 3 for suggested locations.

Location should be out of high traffic areas and away from furniture and draperies due to heat from appliance.

Never obstruct the front opening of the fireplace.

Do not install in the vicinity where gasoline or other flammable liquids may be stored.

Vent pipe routing. Refer to the Venting section found in this manual for allowable venting con- figurations.

These units can be installed in a bedroom. See National Fuel Gas Code ANSI Z233.1/NFPA 54

— (current edition), the Uniform Mechanical Code — (current edition), and Local Building Codes for specific installation requirements.

These units can be installed in a bathroom.

 

 

 

 

A

Flat on Wall

 

 

 

 

B

Cross Corner

E

A

 

B

C

Island**

Y

 

 

D

Room Divider*

 

 

 

 

 

 

 

E

Flat on Wall Corner*

 

 

C

X

F

Chase Installation

 

 

 

Y

6" Minimum

 

 

 

 

D

 

 

**

Island (C) and room divider (D) installation is possible as long

 

 

 

as the horizontal portion of vent system (X) does not exceed

Y

 

 

 

20'. Refer to Installing Horizontal Termination Configuration

 

 

 

 

on Page 15.

F

 

 

*

When you install your fireplace in (D) room divider or (E)

 

 

 

 

flat on wall corner positions (Y), a minimum of 6" clearance

 

 

 

FP1948

must be maintained from perpendicular wall and front of

 

 

 

 

fireplace.

Figure 3 -

Locating Gas Fireplace

73D0024