Monessen Hearth KHLDV400, KHLDV500 fireplace installation, check gas type, Follow all local codes

Models: KHLDV500 KHLDV400

1 64
Download 64 pages 6.61 Kb
Page 21
Image 21
fireplace installation

fireplace installation

KHLDV Series Gas Fireplace

check gas type

Use proper gas type for the fireplace you are installing. If you have conflicting gas type, do not install fireplace. See dealer where you purchased the fireplace for proper fireplace for your gas type or con- version kit.

Installing gas piping to fireplace / burner system location

WARNING

A qualified installer or service person

 

 

must connect appliance to gas supply.

 

Follow all local codes.

 

 

installation items needed

check gas typeA qualified installer or service personCAUTION

For propane/LP units, never connect fireplace directly to the propane/LP supply. This burner system requires an external regulator (not supplied). Install the external regulator between the burner system and propane/LP supply.

Before installing fireplace and burner system, make sure you have the items listed below.

External regulator (supplied by installer)

Piping (check local codes)

Sealant (resistant to propane/LP gas)

Test gauge connection*

Sediment trap (recommended)

Pipe wrench

Tee joint

Equipment shutoff valve*

Approved flexible gas line with gas connector (if allowed by local codes — not provided)

*A CSA design-certified equipment shutoff valve with 1/8" NPT tap is an acceptable alternative to test gauge connection. Purchase the CSA design-certified equipment shutoff valve from your dealer.

For propane/LP connections only, the installer must supply an external regulator. The external regulator will reduce incoming gas pressure. You must reduce incoming gas pressure to between 11 and 13 inches of water. If you do not reduce incoming gas pressure, burner system regulator damage could occur. Install external regulator with the vent pointing down as shown in Figure 28. Pointing the vent down protects it from freezing rain or sleet.

 

100 gallon (min)

External

Propane/LP

Regulator

Supply Tank

 

Vent Pointing

 

Down

 

FP1977

Figure 28 -

External Regulator with Vent Pointing Down (Propane/LP Only)

 

 

Use only new black iron or steel pipe. Internally

 

 

tinned copper or copper tubing can be used

 

CAUTION

per National Fuel Code, section 2.6.3, providing

 

gas meets hydrogen sulfide limits, and where

 

 

 

 

permitted by local codes. Gas piping system

 

 

must be sized to provide minimum inlet

 

 

pressure (listed on data plate) at the maximum

 

 

flow rate (BTU/hr). Undue pressure loss will

 

 

occur if the pipe is too small.

 

 

 

When using copper of flex connectors use only fittings approved for gas connections. The gas control inlet is 3/8" NPT.