Monessen Hearth KHLDV500 KHLDV Series Gas Fireplace, SECURe FIREPLACE to floor or framing

Models: KHLDV500 KHLDV400

1 64
Download 64 pages 6.61 Kb
Page 10
Image 10
KHLDV Series Gas Fireplace

KHLDV Series Gas Fireplace

SECURe FIREPLACE to floor or framing

 

 

The fireplace must be secured to the floor and/or to framing studs as shown in Figure 6. Use two

(2)wood screws or masonry/ concrete screws to secure fireplace to the floor. Use four (4) screws to attach fireplace to framing. The side nailing flanges are 1/2" or 5/8" to accommodate different wall thickness.

Noncombustible Material

6”

Noncombustible Material Must Rise at Least to Top of Stand off

Secure to Floor Behind

Access Panels

Figure 6 -

Secure Fireplace to Floor and Framing Studs

note

Never install combustible materials

 

 

over front face of fireplace.

 

 

Framing Members

Nailing Flange

FP2130

SECURe FIREPLACE to floor or framing All Combustible Materials Must Keep 3/4" Spacing

Finishing Material

NOTE: Any remote wiring (i.e. remote control, wall switch, and optional fan) must be done prior to final finishing to avoid costly reconstruction.

Only noncombustible materials (i.e. brick, tile, slate, steel, or other materials with a UL fire rating of Zero) may be used to cover the black painted face of the appliance. It is permissible to bring com- bustible wall board to the top of the stand-offs on the top and the sides of the unit. A 300°F minimum adhesive may be used to attach facing materials to the black surface. If joints between the finished wall and the fireplace surround are sealed, a 300°F minimum sealant material (General Electric RTV103 or equivalent) must be used.

10

73D0024

Page 10
Image 10
Monessen Hearth KHLDV500 KHLDV Series Gas Fireplace, SECURe FIREPLACE to floor or framing, Finishing Material, 73D0024