KHLDV Series Gas Fireplace | TOUCH SCREEN REMOTE CONTROL OPERATION |
Setting Privacy Code on Transmitter:
Figure 51
The remote transmitter privacy code is preset in facto- ry. In the event of activation or interference from other nearby transmissions, change the
code using the following procedures (learn function must be performed after changing the code):
1.Press the ON/arrow button and the TIMER button at the same time to enter privacy code setup mode.
2.The setup display is shown in the figure. The four digits on the top stand for the privacy code (as the actual DIP switches on Ambient’s
previous remotes). The default
values of the four digits will be all “1” (ON).
3.The first digit will be flashing upon entering the setup mode. Push the ON button to toggle its value between “0” (OFF) and “1”(ON), and push the “OFF” button to jump to the next digit. The next digit will then start flashing and the first one stops flashing. Set up the four digits to your choice.
4.After setting up all the four digits, push “OFF” to finish the process and return to the previous mode.
5.The Signature Command control board then needs to
Performing Learn Function
1.The RF receiver button on the control board in the fire- place must be in the on position before the learn func- tion can begin. Figure 52. With the Command Center master switch in the ON position, use paper clip to de- press the recessed button on Control Board, one beep for RF receiver ON or two beeps for RF receiver OFF.
Battery Door
FP2650
Master Switch
ON
LED
OFFFigure 53
Command Center
transmitter to learn. Another two beeps will be given to confirm a successful learning. Figure 30
| WARNING | Do not use two (2) or more remote control sys- |
| tems in the same area with the same privacy | |
|
| |
|
| code setting, as they will communicate with |
|
| each other. This may cause the appliances to |
|
| malfunction. |
|
|
|
Resetting the transmitter:
If the transmitter is not working properly, reinstall the bat- teries to reset the transmitter.
1.Pull out at least one of the batteries.
2.Press any key on the screen to discharge.
3.Wait for 10 seconds and reinstall the batteries.
Pushing and holding any key for more than 10 seconds until the display refreshes will also reset the transmitter.
nFunctions and Operations
General:
The TSFRSC Remote Control has four (4) operating modes: Manual, Timer, Thermostatic and Smart Mode.
2.Holding the OFF button on the Com- mand Center while turning on the master switch will activate the learn function for the transmitter.
3.After the above op- eration, two beeps will be given and the green LED on the Command Cen- ter will flash for 10 seconds.
RF Receiver
ON/OFF
Control Board
The control system can be set to temperature range between 45° F and 90° F. The blower speed and flame height can be adjusted in the manual, timer and thermo- static mode. The Smart Mode will automatically adjust flame height and blower speed according to the differ- ence between Set and Room temperatures.
The transmitter will operate the remote receiver from 1 foot to a maximum of 30 feet. The distance is reduced when batteries are low.
Manual Mode
Figure 54
In this mode, the TIMER button and the THERMO but- ton will only display “TIMER” and “THERMO”, respec- tively without showing the time and the SET temperature.
Figure 52
4. During the 10 seconds, press the OFF button on the
Pressing the ON/up and OFF/down buttons will change the flame height if none of the menu buttons (TIMER, THERMO, LIGHT, FAN, AUX) are pressed and flashing.
40 | 73D0024 |