Monessen Hearth KHLDV400 cleaning and maintenance, Burner, Pilot and Control Compart- ment

Models: KHLDV500 KHLDV400

1 64
Download 64 pages 6.61 Kb
Page 49
Image 49
cleaning and maintenance

cleaning and maintenance

GN

Turn off gas before servicing fireplace. It

is recommended that a qualified service

I

WARN

technician perform these check-ups at the

 

 

beginning of each heating season

 

 

Burner, Pilot and Control Compart- ment

Keep the control compartment, logs, and burner areas surrounding the logs clean by vacuuming or brushing at least twice a year. Make sure the burner porting, pilot air opening and burner air opening are free of obstructions at all times.

Pilot Flame

The flames from the pilot should be visually checked as soon as the heater is installed and periodically during normal operation. The pilot flame must always be pres- ent when the fireplace is in operation. Figure 66. The pilot flame has three or four distinct flames, one engulfing the thermopile, one engulfing the thermocouple or sensor,

and the remaining reaching to the main burners.

burner

Inspect area around the injector. Remove any lint or foreign material with a brush or vacuum.

Burner Flame

The flames from the burner should be visually checked as soon as the heater is installed and periodically during normal operation. In normal operation, at full rate, and after operating for about 15 to 30 minutes, the flame should be yellow and slightly taller than the rear log. Figure 67

If the flame is blue and only in the center, turn off unit and let cool. After unit is cool, remove logs and check to make sure the back holes in the burner are not covered with rock wool. If the back holes are clear, add more rock wool to the center of the burner. Replace logs.

NOTE: The type of installation, vent system configuration, and wind effects may cause the flame patterns to vary.

KHLDV Series Gas Fireplace

Sensor

Thermopile

Signature

Command

System Pilot

Turn off gas before servicing fireplace. Itis recommended that a qualified servicetechnician perform these check-ups at thebeginning of each heating seasonFP2453

Thermocouple

Thermopile

Millivolt Control

Pilot

FP1943

Figure 66 -

Pilot Flame

Figure 67 -

 

Burner Flame Appearance

LG601

73D0024

49

Page 49
Image 49
Monessen Hearth KHLDV400 cleaning and maintenance, Burner, Pilot and Control Compart- ment, KHLDV Series Gas Fireplace