Monessen Hearth KHLDV400 pRE-INSTALLATIONINFORMATION, Before You Start, firebox framing, 73D0024

Models: KHLDV500 KHLDV400

1 64
Download 64 pages 6.61 Kb
Page 7
Image 7
pRE-INSTALLATION INFORMATION

pRE-INSTALLATION INFORMATION

KHLDV Series Gas Fireplace

Before You Start

Read this homeowner manual thoroughly and follow all instructions carefully. Inspect all contents for shipping damage and immediately inform your dealer if any damage is found. Do not install any unit with damaged, incomplete, or substitute parts. Check your packing list to verify that all listed parts have been received. You should have the following:

Fireplace (Firebox and Burner System)

Log Set

Rock Wool

Noncombustible Panel

ITEMS REQUIRED FOR INSTALLATION

Phillips Screwdriver

Framing Materials

Hammer

Wall Finishing Materials

Saw and/or saber saw Level

Measuring Tape

Pliers

Electric Drill and Bits

Square

Pipe Wrench

Tee Joint

Noncombustible finishing material or dura-rock*

Caulking Material (noncombustible)

Fireplace Surround Material (noncombustible)

Piping Complying with Local Codes

Pipe Sealant Approved for use with Propane/LPG

(Resistant to sulfur compounds)

*Only used if desired to cover painted face other than using tiles or marble. If tiles or marble are used around the face then the non-combustible material is not needed.

firebox framing

Firebox framing can be built before or after the appliance is set in place. Refer to Figure 2 for firebox dimensions and framing. Construct firebox framing following Figure 2 for your specific installation requirements. The framing headers may rest on the top of the firebox standoffs. Do not bring headers below top of standoffs. NOTE: When planning your framing and installation, keep in mind that your gas line will come in on the right side of the box (as you are facing it) and your electricity will come in on the left side.

The firebox may be installed directly on a combustible floor or raised on a platform of an appropriate height. When the firebox is installed directly on carpeting, tile, or other combustible material, other than wood flooring, the firebox shall be installed on a metal or wood panel extending the full width and depth of the enclosure.

WARNING

Unit framing is to be rectangular front to

 

 

back. Failure to do so will cause fire and

 

damage to property.

 

 

WARNING

Do not fill spaces around firebox with insulation or other materials. This could cause a fire.

NOTE

COLD CLIMATE INSULATION

If you live in a cold climate, seal all cracks around your appliance, and wherever cold air could enter the room, with noncombustible material. It is especially important to insulate the outside chase cavity between the studs and under the floor on which the appliance rests, if the floor is above ground level.

73D0024

Page 7
Image 7
Monessen Hearth KHLDV400 pRE-INSTALLATIONINFORMATION, Before You Start, firebox framing, Cold Climate Insulation, 73D0024