How To Use The Vent Graph

KHLDV Series Gas Fireplace

ventING installation

 

 

termination clearances for buildings with combustible and noncombustible exteriors

Dimensions in GFeet G=6" (152mm)

Manual backgroundManual background V Manual backgroundManual background

Combustible – 6" (152 mm)

Noncombustible – 2" (51mm)

Inside Corner

G

V Manual backgroundManual backgroundManual background

G = Combustible 24"(610mm) Noncombustible 18"(457mm)

V

Manual background F Manual background F=6" (152mm)

Outside Corner

H

V

J

Combustible &

Noncombustible

H = 24" (610mm)

J = 20" (508mm)

 

D

C

C

 

V

Manual background E Manual background

C = Maximum depth of 48" (1219mm) for alcove location

D = Minimum width for back wall of alcove location Combustible - 38" (965mm) Noncombustible - 24" (610mm)

E = Clearance from corner in alcove location

Combustible - 6" (152mm)

Noncombustible - 2" (51mm)

Balcony with No Side Wall

Balcony with Perpendicular

Figure 9 -

Side Wall

 

Allowable Venting Chart

 

How To Use The Vent Graph

The Vent Graph should be read in conjunction with the following vent installation instructions to determine the relationship between the vertical and horizontal dimensions of the vent system.

1.Determine the height of the center of the horizontal vent pipe exiting through the outer wall. Using this dimen- sion on the Sidewall Vent Graph below, locate the point intersecting with the slanted graph line.

2.From the point of this intersection, draw a vertical line to the bottom of the graph.

3.Select the indicated dimension, and position the fire- place in accordance with same.

Example: If the vertical dimension from the floor of the fireplace is 11' (3.4 m) the horizontal run to the face of the outer wall must not exceed 16' (4.9 m).

Sidewall Vent Graph showing the relationship between vertical and horizontal dimensions for a Direct Vent flue system.

Alcove Location

 

 

Dimensions in

 

40

 

 

Feet

 

 

 

 

Vertical

38

 

 

 

36

 

 

 

34

 

 

 

 

 

 

Dimension

32

 

 

 

30

 

 

 

28

 

 

 

26

 

 

 

 

 

 

From the Floor of Unit

24

 

 

 

22

 

 

 

20

 

 

 

18

 

 

eg: A

16

 

 

14

 

 

PipeVentHorizontal

12

 

 

 

 

 

to

10

 

 

 

 

 

 

the

8

 

 

 

 

 

 

Center

6

 

 

 

4

 

 

 

2

 

 

 

of

 

 

 

the

2

4

6

8 10 1214 16 1820

 

 

Horizontal dimension from the finished outside wall

Figure 10 -

to the center of the pipe on the fireplace

 

Rear Wall Venting Graph

14

73D0024

Page 14
Image 14
Monessen Hearth KHLDV500 How To Use The Vent Graph, KHLDV Series Gas Fireplace, ventING installation, Feet, Dimensions in