Monessen Hearth KHLDV500 KHLDV Series Gas Fireplace, Touch Screen Remote Control Operation

Models: KHLDV500 KHLDV400

1 64
Download 64 pages 6.61 Kb
Page 42
Image 42
Blower Speed Control

KHLDV Series Gas Fireplace

TOUCH SCREEN REMOTE CONTROL OPERATION

 

 

is no manual flame height adjustment. The fan speed will also automatically adjust if turned on.

NOTE: When entering the Smart Mode function there will be a 10 second delay for the flame and blower adjust- ment. When Smart Mode operates automatically there can be up to a 3 minute delay for flame/blower adjust- ment. Smart Mode checks temperatures every 3 minutes. Also see AUX Control.

1.When Set Temp. is 3° F or higher than Room Temp., flame height will be on High.

2.When Set Temp. is 2° F higher than Room Temp., flame height will be on Medium.

3.When Set Temp. is 1° F higher than Room Temp., flame height will be on Low.

4.When Set Temp. is equal to Room Temp., flame height does not change (stays on low).

5.When Set Temp. is lower than Room Temp., the fire- place will be shut off.

6.When Set Temp. is 1° F higher than Room Temp., again the flame height will be on Low.

7.the fan speed follows the flame height, if the fan is turned on.

To exit Smart Mode and shut off the fireplace;

a.push and hold the THERMO buttons for 3 sec- onds, Or

b.press the OFF button, Or

c. slide down on the arrow buttons.

To shut off the Smart Mode option and return to regular thermostat mode, press and hold the THERMO button and the ON/UP button at the same time for 3 seconds again.

Blower Speed Control

Figure 58

NOTE: Blower will only work with flame on.

The blower speed control function is used to adjust the speed of the blower connected to the Signature Command System. There are four speed levels, Off, Low, Medium, High.

1.Press the FAN button to enter the blower speed control mode.

The fan icon will start flashing.

Figure 58

2.Press the ON/up and OFF/down button to increase/de- crease the blower speed.

3.Press the fan button again to confirm the speed set- ting. If the fireplace is on, the blower speed will take effect right away; if the fireplace is off, the receiver will remember this setting and the blower is still off (see blower On Delay and Off Delay in the next section).

4.After the signal is sent, the ON/up and OFF/down but- tons become flame height controller again.

5.When the fan button is flashing, slide up and down on the arrow buttons will turn the blower speed to High or Off directly without pressing the fan button again to confirm.

6.If the blower is turned on using the FAN button, the blower speed will adjust automatically when using Smart Mode (See Smart Mode section).

Blower On Delay Time and Off Delay Time Setup Figure 59

1.Hold the FAN button for 3 sec- onds until two numbers ap- pear on the LCD screen. The left number is blower On Delay and the right number is blower Off Delay Time.

2.When the first number is flash- ing, use the ON/up button to set the desired On Delay Time from 0 to 15 min.

3.Press the OFF/down button to jump to the Off Delay Time

setup.

Figure 59

 

4.When the second number is

flashing, use the ON/up button again to set the desired Off Delay Time from 0 to 15 min.

5.Press the OFF/down button again to finish the setup and the new settings will be transmitted to the receiv- er.

6.The default settings are 5 minutes for the On Delay Time and 8 minutes for the Off Delay Time, as shown.

Light Brightness Control

Figure 60

The light brightness control func- tion is used to adjust the bright- ness of the light bulbs connected to the AC module on the Signa- ture Command System. There are four light brightness levels defined: Off, Low, Medium, High

1.Press the LIGHT button to en- ter the light brightness control mode. The LIGHT icon will start flashing.

2.Press the On/up and OFF/ down buttons to increase/de-

crease the light brightness

Figure 60

 

(Off-Low-Medium-High).

 

3.Press the light button again to confirm the setting. The new setting will be transmitted to the receiver.

42

73D0024

Page 42
Image 42
Monessen Hearth KHLDV500 KHLDV Series Gas Fireplace, Touch Screen Remote Control Operation, Blower Speed Control, 73D0024