Monessen Hearth KHLDV500 Lighting pilot for the first time, millivolt - OPERATING INSTRUCTIONs

Models: KHLDV500 KHLDV400

1 64
Download 64 pages 6.61 Kb
Page 28
Image 28
millivolt - OPERATING INSTRUCTIONs

KHLDV Series Gas Fireplace

millivolt - OPERATING INSTRUCTIONs

 

 

 Lighting pilot for the first time Lighting pilot for the first time approved leak testing methoddanger

approved leak testing method

You may check for gas leaks with the following methods only:

Soap and water solution

An approved leak testing spray

WARNING

If using a soap and water solution to test for leaks, DO NOT spray solution onto control body.

• Electronic sniffer

danger

Never check for gas leak with open flame!

 

 

 

NOTE: Remove any excessive pipe compound from the connections. Excessive pipe compound can set off electronic sniffers.

Check for gas leaks in each of the following locations:

Pipe from the gas supply line connection to the gas valve

Burner connections

• Field made joints / gas shutoff valve

Pilot

Factory made joints

Each joint or connection

All joints on valve and control body

WARNING

Lighting pilot Never check for gas leak with open flame!Lighting pilot

The control has an interlock device that does not allow the lighting of the fireplace up to the moment the safety device of the flame has not interrupted the gas flow. After that period of time (when the magnet is closed), it is possible to start the lighting operation.

The gas control knob is designed to be operated by hand. DO NOT use any tools during this operation. Damaged knobs may result in serious injury.

1.Depress and turn knob counterclockwise Manual background to pilot position.

2.Depress fully and hold pilot gas knob. Depress piezoigniterasmanytimesasneededtoignitepilot. Keep knob fully depressed for a few seconds. Release and check that pilot continues to burn.

If the pilot does not stay lit, repeat steps 1 and 2.

 

O

T

N

O

 

L

 

I

 

P

 

 

F

 

F

 

O

Figure 39 - PILOT

Pilot Position

Continued on next page