OUTSIDE COMBUSTION AIR PRECAUTIONS & RECOMMENDATIONS
OUTSIDE COMBUSTION AIR RECOMMENDATIONS (CONTINUED)
1.Extremely long runs and numerous turns in the duct leading from the fireplace to the combustion air assembly should be avoided. These conditions will increase the resistance to the free flow of air through the duct. Refer to Figures 1, 23, and 24 for methods of installing the outside air for combustion assemblies.
2.The combustion air assembly should be located at an exterior location, which is not likely to be accidentally blocked in any manner. The assembly should be located above the snow line to prevent blockage by snow accumulation.
3.The combustion air inlet assembly should never be mounted in a garage or storage area where combustible fumes such as gasoline might be drawn into the fireplace.
4.Combustion air can be drawn form the crawl space under a house when an adequate supply of air is provided by open ventilation.
5.Do not take combustion air from attic space or garage space.
FIGURE 24
NAIL
HOLES
SCREWS
6" DIA. HOLE FOR
COMBUSTION AIR ASSEMBLY
FOR MODEL NO.
OUTSIDE AIR CONTROL
LEVER (LIFT TO OPEN,
PULL DOWN TO CLOSE)