PRODUCT DATA SHEETS

Interior Water Filtration System

Model 67003523-750 Capacity 750 Gallons (2839 Liters)

Standard 42 for the reduction of Chlorine Taste and Odor, Particulate

Class I*; and against NSF/ANSI Standard 53 for the reduction of Lead,

Mercury, Atrazine, Toxaphene, Cysts, Turbidity, Asbestos and Lindane.

This system has been tested according to NSF/ANSI Standards 42 and 53 for the reduction of the substances listed below. The concentration of the indicated substances in water entering the system was reduced to a concentration less than or equal to the

 

 

 

 

 

 

 

 

 

 

Standards 42 and 53.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Substance Reduction

NSF Reduction

Average

 

 

 

 

Maximum

 

Average

Minimum%

Average%

 

 

 

 

 

 

 

 

 

Requirements

 

 

Concentration

 

 

 

 

Reduction

Reduction

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Chlorine Taste/Odor

50% reduction

1.88 mg/L

2.0 mg/L ± 10%

 

0.06 mg/L

**

0.05 mg/L

96.84

>97.26

Particulate Class I

*

85% reduction

5,700,000 #/mL

At least 10,000

 

69,000 #/mL

30,583 #/mL

98.94

99.52

 

 

 

 

 

 

 

 

particles/mL

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Contaminant

 

NSF Reduction

Average

 

 

 

 

Maximum

 

Average

Minimum%

Average%

 

 

 

 

 

 

Reduction

 

Requirements

 

 

Concentration

 

 

 

 

Reduction

Reduction

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Lead: @ pH 6.5

 

0.010 mg/L

0.153 mg/L

0.15 mg/L ± 10%

 

< 0.001mg/L

 

< 0.001mg/L

>99.29%

>99.35%

Lead: @ pH 8.5

 

0.010 mg/L

0.150 mg/L

0.15 mg/L ± 10%

 

< 0.001mg/L

 

< 0.001mg/L

>99.29%

>99.33%

 

 

 

 

 

 

 

 

 

 

 

Mercury: @ pH 6.5

 

0.002 mg/L

0.006 mg/L

0.006 mg/L ± 10%

 

0.0005 mg/L

 

0.0003 mg/L

90.91

95.70

Mercury: @ pH 8.5

 

0.002 mg/L

0.006 mg/L

0.006 mg/L ± 10%

 

0.0015 mg/L

 

0.0008 mg/L

75.93

86.22

 

 

 

 

 

 

 

 

 

 

 

 

Toxaphene

 

0.003 mg/L

0.015 mg/L

0.015 ± 10%

 

 

<0.001mg/L

 

< 0.001mg/L

91.67%

92.97%

 

 

 

 

 

 

 

 

 

 

 

Atrazine

 

0.003 mg/L

0.009mg/L

 

0.009 mg/L ± 10%

< 0.002 mg/L

 

< 0.002 mg/L

75.31%

76.99%

 

 

 

 

 

 

 

 

 

 

 

 

Asbestos

 

99%

 

155 MF/L

107 to 10 8

††

<1 MF/L

 

<1 MF/L

>99.99%

>99.99%

Live Cysts

 

>99.95%

166,500 #/L

50,000/L min.

 

<1 #/L

 

<1 #/L

>99.99

>99.99

Turbidity

 

0.5 NTU

10.7 NTU

11 ± 1 NTU

 

0.49 NTU

 

0.31 NTU

95.2

97.09

 

 

 

 

 

 

 

 

 

 

 

 

Lindan

 

0.0002 mg/L

0.002 mg/L

0.002 ± 10%

 

 

<0.0001mg/L

 

0.000 mg/L

96.50%

98.72%

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Test Parameters: pH = 7.5 ± 0.5 unless otherwise noted. Flow = 0.78 gpm (1.9 Lpm). Pressure = 60 psig (413.7 kPa). Temp. = 68 to 71.6 (2 C to 22 ).

replacement requirements be carried out for the product to perform as advertised.

’s rated life is used, the yellow (Order)

’s rated life is used, the red (Replace) light comes on, and it is recommended that

The product is for cold water use only.

Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after

Refer to the back cover or “Accessories” section for the Manufacturer ’s name, address and telephone number.

Application Guidelines/Water Supply Parameters

Water Supply

City or Well

Water Pressure

35 - 100 psi (241 - 689 kPa)

Water Temperature

33 - 10 F (1 - 38 C)

Service Flow Rate

0.78 gpm (2.9 L/min.) @ 60 psi.

 

 

*Class I particle size: >0.5 to <1 um

**Test requirement is at least 100,000 particles/mL of AC Fine Test Dust.

These contaminants are not necessarily in your water supply. Performance may vary based on local water conditions.

†† Fibers greater than 10 um in length

 

Based on the use of Cryptosporidium parvum oocysts

20

® NSF is a registered trademark of NSF International.

Page 21
Image 21
Marvel Group 36 PRO+ manual Product Data Sheets, Interior Water Filtration System