Master Lock B70CEA Assembly, Fuels, Ventilation, For 100,000 and 150,000 BTU/HR Models only

Models: B150CEA B100CEA B35CEA B70CEA

1 48
Download 48 pages 33.99 Kb
Page 4
Image 4

R

PORTABLE FORCED AIR HEATERS

ASSEMBLY

(FOR 100,000 AND 150,000 BTU/HR MODELS ONLY)

These models are furnished with wheels and handles. Wheels, handles, and the mounting hardware are found in the shipping carton.

Tools Needed

Medium Phillips Screwdriver

3/8" Open or Adjustable Wrench

Hammer

1.Slide axle through wheel support frame. Install wheels on axle.

IMPORTANT: When installing wheels, point extended hub of wheels toward wheel support frame (see Fig- ure 3).

2.Place cap nuts on axle ends. Gently tap with hammer to secure.

3.Place heater on wheel support frame. Make sure air inlet end (rear) of heater is over wheels. Line up holes on fuel tank flange with holes on wheel sup- port frame.

4.Place front handle and rear handle on top of fuel tank flange. Insert screws through handles, fuel tank flange, and wheel support frame. Attach nut finger tight after each screw is inserted.

5.After all screws are inserted, tighten nuts firmly.

FUELS

WARNING: Use only kerosene or No. 1 fuel oil to avoid risk of fire or explosion. Never use gaso- line, naphtha, paint thinners, al- cohol or other highly flammable fuels.

Do not use heavy fuels such as No. 2 fuel oil or No. 2 Diesel. Using heavy fuels will result in:

clogged fuel filter and nozzle

carbon build up on spark plug

use of non-toxic anti-icer in fuel during very cold weather

IMPORTANT: Use a KEROSENE ONLY container. Be sure storage container is clean. Foreign matter such as rust, dirt, or water will cause the flame-out control to shut down heater. Foreign matter may also re-

Front Handle

quire you to clean fuel system often.

Screw

Hot Air

Outlet

Fuel Tank

Flange

Wheel

Support

Frame

WheelNut

Cap Nut

Rear

Handle

Air

Inlet

Extended

Axle Hub

VENTILATION

WARNING: Follow the mini- mum fresh, outside air ventila- tion requirements. If proper fresh, outside air ventilation is not pro- vided, carbon monoxide poison- ing can occur. Provide proper fresh, outside air ventilation be- fore running heater.

Provide a fresh air opening of at least 2800 square cm (three square feet) for each 100,000 Btu/Hr rating. Provide extra fresh air if more heaters are being used.

Example: A 150,000 Btu/Hr heater re- quires one of the following:

a 4.88 m (16 foot) wide two-car garage door raised 8.59 cm (3.38 inches)

a 2.75 m (9 foot) wide single-car garage door raised 15.24 cm (six inches)

two, 76.2 cm (thirty-inch) windows raised 30.48 cm (twelve inches)

Figure 3 - Wheel and Handle Assembly, 100/150,000 Btu/Hr Models Only