APPENDIX

ELX8 -60

When installing one primary disk and auxiliary disk

(1)When power is supplied to ELX8 -60, “Disk Manager” runs automatically after rebooting. If not, run it manually in “MenuàUtility àDisk Manager”.

(2)There is a HDD that is indicated as “[F] IntA”.

(3)Select a HDD for installing as primary disk. (IntA or IntB)

(3)Press the “Apply ” button after selecting action as “Add”. Then [F] is changed to [*]. If IntB is added as primary disk, it will be placed at upper list.

(5)Select a HDD for installing as auxiliary disk.

(6)Press the “Apply ” button after selecting action as “Add”. Then [F] is changed to [*].

(7)Select a primary disk, and press the “Apply ” button after selecting action as “Format” and setting the size of alarm partition. Then [*] is changed to [R].

(8)Select an auxiliary disk, and press the “Apply ” button after selecting action as “Format” and setting the size of alarm partition. Then [*] is changed to [R].

<Note>

Alarm partition can be set at only primary disk. So it is indicated as “Disable” in case of formatting.

(9)Press the [EXIT] button to shut down “Disk Manager”. (If recording schedule is set, ELX8-60 will start recording.)