Maytag 16010107 service manual HI-LIMIT Thermostat, To Remove Lift-Off Door

Models: 16010107

1 50
Download 50 pages 51.35 Kb
Page 17
Image 17

HI-LIMIT THERMOSTAT

The HI-Limit Thermostat is mounted to range main back. The purpose of this thermostat is to break line voltage to oven control in case of a runaway temperature. Range may be removed from cabinetry for rear serviceability.

Contacts normally closed

Close Temperature - 250 ± 11ºF

Open Temperature - 300 ± 8ºF

Thermostat Replacement

1.Disconnect the appliance from power source before servicing.

2.Slide unit out of installation.

3.Remove screws securing main back shield and remove shield.

4.Remove two (2) screws securing thermostat to range main back.

5.Disconnect wiring.

6.Replace in reverse order.

OVEN DOOR(S)

Do not place excessive weight on an open oven door or stand on an opened door as, in some cases, it could cause the range to tip over, breakage of the door, or serious injury.

16010107

CAUTIONS:

Do not attempt to open or close door or operate oven until door is properly replaced.

Hinge arms are spring mounted and will slam shut if accidentally hit.

Never place hand or fingers between the hinges and the front oven frame. You could be injured if hinge snaps back.

Both the upper and lower oven doors are removable.

To Remove Lift-Off Door:

Open door to stop position. In stop position door is open approximately 4”. Grasp door as illustrated. Lift up evenly until door clears the hinge arms.

DO NOT USE DOOR HANDLE TO LIFT DOOR.

To Replace:

1.Grasp door at each side.

2.Align slots in the door with the hinge arms on the range.

3.Slide the door down onto the hinge arms until the door is completely

Section 3. Component Description