![](/images/new-backgrounds/1228543/2285433x1.webp)
CONNECT WATER
2FILL HOSES TO
WASHER
Tightly push one flat rubber washer into one end of each water fill hose and attach this end of hose to washer. HOT and COLD connec- tions are identified by letters H and C stamped into washer cabinet and by HOT and COLD printed on water fill hoses.
In most cases, hoses should cross when attached to correct water tem- perature faucet.
Tighten hose connections by hand until snug, then another 1/4 turn with pliers. DO NOT
H C
HOT |
COLD |
Push rubber washer |
into end of fill hose. |
CONNECT WATER
3FILL HOSES TO
FAUCETS
Before connecting hoses to water supply, turn on faucets and flush lines for approximately 2 minutes to remove foreign matter that could clog filter screens in water mixing valve or fill hoses.
Tightly push one screened filter washer onto remaining end of each water fill hose. Attach water hoses
SECURE
4DRAIN HOSE TO DRAIN
Remove drain hose from shipping position on rear of washer by unhooking hose from retainer clamp. Use beaded
IMPORTANT: To prevent siphoning, do not place ribbed portion of drain hose into standpipe. Avoid
For standpipe installation below 36" (91.4 cm), install Siphon Break Kit part #562P3.
For standpipe installation above 48" (121.2 cm), install a check valve to prevent water from flowing back into washer. Available from local hard- ware store.
to HOT and COLD faucets. BE
SURE HOT WATER HOSE IS
CONNECTED TO HOT WATER
FAUCET.
Tighten hose connections by hand until snug, then another 1/4 turn with pliers. DO NOT
Turn on water and check for leaks. If leaks are found, retighten hose couplings. Continue tightening and rechecking until no leaks are found.
| STANDPIPE | |
| Standpipe | |
| adapter | |
| (avoid | |
| ||
36" (min.) | seal) | |
Beaded | ||
from floor | ||
| ||
| strap | |
| TUB |
72" (max.) 36" (min.) from floor
Faucets
HOT
COLD
Screen Filters
HOT | COLD | Hoses |
|
|
WALL UNIT
Beaded strap
36" (min.) from floor
Beaded
2