Page 6
Image 6

Product Specifications

Model

 

HR640DJRT

HR640SJRS

HR640DJRS

HR640SJLS

HR640DJLS

 

 

 

 

 

 

 

Tank Capacity

40

40

40

40

40

In Gal.

 

*Element

Upper

4500

4500

4500

Wattage

 

 

 

 

 

 

Lower

4500

4500

4500

4500

4500

at 240 Volt

Recovery Rate Upper

20

20

20

In Gals. Per Hr.

 

 

 

 

 

 

 

 

 

 

 

 

@ 90°F Rise

Lower

20

20

20

20

20

Diameter

 

18”

20 1/2”

20 1/2”

25”

25”

Height

 

59 1/2”

44”

44”

32 1/4”

32 1/4”

Maximum Fuse or

30

30

30

30

30

Circuit Breaker Size

Minimum

 

10

10

10

10

10

Wire Size (Gauge)

 

 

 

 

 

 

 

Model

 

HR652SJRT

HR652DJRT

HR650SJRS

HR650DJRS

HR650SJLS

 

 

 

 

 

 

Tank Capacity

50

50

50

50

50

In Gal.

 

*Element

Upper

4500

4500

Wattage

 

 

 

 

 

 

Lower

4500

4500

4500

4500

4500

at 240 Volt

Recovery Rate Upper

20

20

In Gals. Per Hr.

 

 

 

 

 

 

 

 

 

 

 

 

@ 90°F Rise

Lower

20

20

20

20

20

Diameter

 

20 1/2”

20 1/2”

22”

22”

26 1/2”

Height

 

54”

54”

48”

48”

34”

Maximum Fuse or

30

30

30

30

30

Circuit Breaker Size

Minimum

 

10

10

10

10

10

Wire Size (Gauge)

 

 

 

 

 

 

 

Model

 

HR650DJLS

HR666SJRT

HR666DJRT

HR682SJRT

HR682DJRT

 

 

 

 

 

 

Tank Capacity

50

66

66

80

80

In Gal.

 

*Element

Upper

4500

4500

4500

Wattage

 

 

 

 

 

 

Lower

4500

4500

4500

4500

4500

at 240 Volt

Recovery Rate Upper

20

20

20

In Gals. Per Hr.

 

 

 

 

 

 

 

 

 

 

 

 

@ 90°F Rise

Lower

20

20

20

20

20

Diameter

 

26 1/2”

22”

22”

24”

24”

Height

 

34”

60 1/4”

60 1/4”

60 1/2”

60 1/2”

Maximum Fuse or

30

30

30

30

30

Circuit Breaker Size

Minimum

 

10

10

10

10

10

Wire Size (Gauge)

*Standard element wattages are shown. Other element wattages (up to the maximum shown) are available when specified. *Wiring size based on standard 60°C copper wire. If distance from fuse box to water heater is more than 90 feet, refer to your local

electrical code.

6

Page 6
Image 6
Maytag HR6120DJRT, HR652SJRT, HR682SJRT, HR666DJRT, HR652DJRT, HR666SJRT, HR682DJRT, HR640SJRS Product Specifications, Model