SECTION X
TROUBLESHOOTING
WARNING: YOU MUST DISCONNECT and LOCKOUT THE ELECTRIC SUPPLY and THE GAS SUPPLY BEFORE ANY COVERS or GUARDS ARE REMOVED FROM THE MACHINE TO ALLOW ACCESS FOR CLEANING, ADJUSTING, INSTALLATION, or TESTING OF ANY EQUIPMENT per OSHA (Occupational Safety and Health Administration) STANDARDS.
The information provided will help isolate the most probable component(s) associated with the difficulty described. The experienced technician realizes, however, that a loose connection or broken/shorted wire may be at fault where electrical components are concerned ... not necessarily the suspect component itself. Electrical parts should always be checked for failure before being returned to the factory.
IMPORTANT: When replacing blown fuses, the replacement must be of the exact rating as the fuse being replaced. The information provided should not be misconstrued as a handbook for use by an untrained person in making repairs.
WARNING: ALL SERVICE and TROUBLESHOOTING SHOULD BE PERFORMED BY A QUALIFIED PROFESSIONAL or SERVICE AGENCY.
WARNING: WHILE MAKING REPAIRS, OBSERVE ALL SAFETY PRECAUTIONS DISPLAYED ON THE DRYER or SPECIFIED IN THIS MANUAL.
MICROPROCESSOR CONTROLLER (COMPUTER) MODELS
A.No light emitting diode (L.E.D.) display (for microprocessor controller [computer] models ONLY)...
1.Service panel fuse blown or tripped breaker.
2.Blown control circuit L1 or L2
3.Failed microprocessor controller (computer).
4.Failed control step down transformer (for 380 volts or higher models ONLY).
B.Drive motor is not operating (does not start)...
1.Microprocessor controller (computer) motor indicator dot and relay output L.E.D. indicator dots are on...
a. Failed drive motor contactor (relay).
44