4) Gas supply may have too low a heating value.
NOTE: Lint accumulation on the sensor bracket can act as an insulator, which will affect the accuracy of the Automatic Drying Cycle.
K.Main burners are burning with a yellow flame (for Gas Models ONLY)...
1.Poor air and gas mixture (too much gas or not enough air) at the burner...
a.Not enough
b.Restriction in the exhaust ductwork.
c.Gas pressure is too high.
d.Impellor (fan and blower) is rotating in the wrong direction (for
e.Burner orifice size (drill material size [D.M.S.]) too large for application (i.e., high elevation).
L.Condensation on main door glass...
1.Too long, undersized, or improperly installed ductwork.
2.Back draft damper is sticking in the partially closed position.
M.Scraping noise at basket (tumbler) area...
1.Check for obstruction caught in basket (tumbler) and wrapper area.
2.Basket (tumbler) is out of proper alignment...
a.Check both the vertical alignment and lateral alignment.
b.Check for gap between the front panel and basket (tumbler)...bearing setscrews may have come loose, and basket (tumbler) walked forward or backward.
3.Loose basket (tumbler) tie rod.
4.Failed basket (tumbler) support.
N.Excessive noise or vibration...
1.Dryer is not leveled properly.
2.Impellor (fan and blower) is out of balance...
a.Excessive lint build up on impellor (fan and blower).
b.Failed impellor (fan and blower).
56