b.Failed arc suppressor (A.S.) board (for Reversing Models ONLY).

c.Failed drive motor.

2.Microprocessor controller (computer) motor indicator dot and relay output light emitting diode (L.E.D.) indicator dots are on, but motor output L.E.D. indicator is off...

a.Failed microprocessor controller (computer).

C.Drive motor (Reversing Models ONLY) operates in one (1) direction only...stops and restarts in the same direction...

1.Failed reversing contactor (relay).

2.Failed arc suppressor (A.S.) board.

3.Failed microprocessor controller (computer)...check output indicator.

D.Drive motor operates okay for a few minutes, then stops and will not restart...

1.Motor is overheating and tripping out on internal overload protector...

a.Motor air vents clogged with lint.

b.Low voltage to motor.

c.Failed motor.

d.Basket (tumbler) is binding...check for an obstruction.

e.Failed idler bearings or basket (tumbler) bearings.

f.Failed blower (impellor and fan) is out of balance (for Non-Reversing Models ONLY).

E.Blower and fan motors are not operating (does not start)...

1.Microprocessor controller (computer) motor indicator dot and relay output L.E.D. indicator dots are on...

a.Failed blower (impellor and fan) motor contactor (relay).

b.Failed arc suppressor (A.S.) board.

c.Failed blower (impellor and fan) motor.

2.Microprocessor controller (computer) “door” L.E.D. is on but motor output L.E.D. indicator is off...

a.Failed microprocessor controller (computer).

F.Blower and fan motors (Reversing Models ONLY) operate okay for a few minutes, then stops and will not restart...

45

Page 49
Image 49
Maytag MDG-75 installation manual Blower and fan motors are not operating does not start