2.Impellor (fan and blower) is out of balance...
a.Excessive lint build up on impellor (fan and blower).
b.Failed impellor (fan and blower).
3.Loose basket (tumbler) tie rod.
4.Failed basket (tumbler) support.
5.Loose motor mount.
6.Failed idler bearings or basket (tumbler) bearings.
7.
8.Basket (tumbler) bearing setscrews are loose.
9.Failed motor bearing.
TIMER MODELS
A.Dryer will not start...both drive motor and blower (impellor/fan) motor are not operating and indicator light is off...
1.Service panel fuse blown or tripped breaker.
2.Dryer control circuit L1 or L2
3.Open in main door switch...
a.Main door is not closed ALL the way.
b.Main door switch is out of proper adjustment.
c.Failed main door switch.
d.Broken connection/wire somewhere in the main door switch circuit.
4.Failed
5.Failed 24 VAC step down transformer or a fault in the wiring.
6.Failed heat timer.
7.Failed control step down transformer (for 380 volts or higher models ONLY).
B.Drive motor is not operating (does not start)...
1.Failed drive motor contactor (relay).
2.Failed reversing timer (for Reversing Models ONLY). 52