Metal Handle

Connecting the Water Supply Installation

To Install:

1. Align door handle clips to the studs attached to the freezer door.

2.Ensure the large hole in Manual background the mounting clip is

positioned to the right on both ends of the handle.

3.Rotate the handle so that the handle is flat against the door.

4.Grasp the handle firmly and slide handle to the right.

To Remove:

1.With both hands, firmly grasp the handle toward the right side.

2.Slide toward the left, lift and remove from the surface.

Metal Handle

Materials Needed:

332” Allen wrench

Gloves to protect hands

Note: Metal handles can scratch doors.

To Remove:

• Loosen set screws in handle using 332” Allen wrench.

• Repeat the procedure on all screws.

To Replace:

• Align handle with the mounting posts.

Fully tighten all set screws to secure handle

in place.

Connecting the Water Supply

Manual background WARNING

To reduce the risk of injury or death, follow basic precautions, including the following:

Read all instructions before installing ice maker.

Do not attempt installation if instructions are not understood or if they are beyond personal skill level.

Observe all local codes and ordinances.

Do not service ice maker unless specifically recommended in Use and Care Guide or published user-repair instructions.

Water damage due to an improper water connection may cause mold/mildew growth. Clean up spills or leakage immediately!

Manual background CAUTION

To avoid property damage or possible injury, follow basic precautions, including the following:

Consult a plumber to connect 14” O.D. copper tubing to household plumbing to assure compliance with local codes and ordinances.

Confirm water pressure to water valve is between 35 and 100 pounds per square inch, 20 pounds per square inch without filter.

Do not use a self-piercing, or 316” saddle valve. Both reduce water flow and can become clogged over time, and may cause leaks if repair is attempted.

Tighten nuts by hand to prevent cross threading. Finish tightening nuts with pliers and wrenches. Do not over-tighten.

Wait two to three hours before placing refrigerator into final position to check and correct any water leaks. Recheck for leaks after 24 hours.

Verify the copper tubing under the sleeve is smooth and free from defects. Do not reuse an old sleeve.

8

Page 9
Image 9
Maytag MFI2266AEW important safety instructions Connecting the Water Supply, Metal Handle, Installation