Maytag DGRSC, RJGR manual Troubleshooting Procedures, Problem, Possible Cause, Correction

Models: DGRSC RJGR

1 20
Download 20 pages 29.89 Kb
Page 11
Image 11
Troubleshooting Procedures

Troubleshooting Procedures

!WARNING

To avoid risk of electrical shock, personal injury or death; disconnect power and shut off gas to unit before servicing, unless testing requires power.

Problem

Possible Cause

 

Poor ground at ignitor

Burners will not ignite; no

Weak or failed spark module

spark at top burner.

Low gas pressure

 

 

 

No 120 VAC to range

 

Micro switch contacts not closing

Burner will not ignite. No

Faulty wiring. Bad connection at burner

electrode and electrode socket

spark to burner ignitors

 

when burner knob is rotated

 

to “LITE” position.

 

 

Inoperative spark module

 

Electrode dirty

 

Cracked or broken electrode, electrode

 

wire or electrode socket

 

 

 

Check for cracked ignitor or pinched ignitor

 

wire

 

Poor continuity to ignitor

No spark or only random

Bad ground connection or lack of continuity

to ground or ignitor

spark at one ignitor.

 

 

Cracked or broken ignitor extension lead ...

 

 

 

Shorted valve switch/harness

Unit continues to spark after

 

knob is turned to OFF

Switch has slipped off the valve

position.

 

 

 

Correction

Verify spark.

Replace spark module.

Verify pressure 4” WCP for natural, 10” WCP for LP.

Verify voltage at wall outlet.

Check wiring against appropriate wiring diagram, Verify all terminals and connections are correct and tight. Check micro switch contacts.

Check wiring against appropriate wiring diagram. Verify all terminals and connections are correct and tight.

Check module according to testing procedures information.

Clean electrode.

Replace electrode.

Replace ignitor lead or electrode.

Verify spark.

Tighten ground connection and correct any breaks in ground path from ignitor path to unit ground path.

Replace ignitor lead.

Replace switch/harness. If shorting is caused by excessive spillovers, customer education is advised.

Carefully reposition switch on valve and rotate from OFF to high, several times to verify switch is not broken.

©2004 Maytag Services

16023219

11

Page 11
Image 11
Maytag DGRSC, RJGR manual Troubleshooting Procedures, Problem, Possible Cause, Correction