CHASSIS INSTALLATION

CHASSIS INSTALLATION

1.Inspect the ground wire (Figure 6) on the unit and ensure it is attached to the left side panel. If not, attach the wire to the panel.

2.Remove the mounting screw from the left hand side of the existing sleeve (Figure 6). Place the screw through the eyelet on the unattached end of the ground wire of the unit and reinsert into its mounting hole.

Ground

Wire

Mounting

Screw

Figure 6

3.Install the 1/2” x 1/2” supplied gasket foam around the top and two sides of the chassis (Figure 7).

Foam

Clip Screw

Figure 8

FRONT PANEL INSTALLATION

Discharge Air Grille

Airflow Direction Change - Optional

If you wish to change the direction of airflow from up to down, remove the four screws holding the Discharge Air Grille in place (Figure 9). Drop out the grille and rotate 180°. Ensure the notches on the grille face up. Replace the grille and secure in place with the removed screws.

Screws

(4 places typ.)

Discharge Air Grille

Figure 7

4.Carefully slide the chassis into the sleeve. Ensure that the ground wire is not pinched or in the path of the

condenser fan.

5. Fasten the supplied clips to the exposed sides of the unit using the two #8 x 3/8” blunt sheet metal screws provided (Figure 8).