Maytag Thru-the-Wall Room Air Conditioner Unit Operation, High Cool, Medium Cool, Low Cool

Models: Thru-the-Wall Room Air Conditioner

1 8
Download 8 pages 23.65 Kb
Page 6
Image 6
Unit Operation

HIGH COOLMEDIUM COOL WARNING

This air conditioner is not meant to provide unattended cooling or life support for persons or animals who are unable to react to the failure of this product.

The failure of an unattended air conditioner may result in extreme heat in the conditioned space causing overheating or death of persons or animals. Take proper precautions to avoid unattended operation.

VOLTAGE MEASUREMENTS

Before connecting the unit, measure the supply voltage. Voltage must fall within the voltage utilization range given in Table 1.

Operating Voltage

Unit Voltage

Voltage Utilization Range

Rating

Minimum

Maximum

230/208

197

253

115

103

126

Table 1

Operating Voltage

Unit Operation

Two rotary knobs (Figure 10) control temperature and operational modes. They are located to the top left of the cabinet front.

THERMOSTAT SETTING

OOLE

 

 

 

 

 

 

C

R

 

 

E

C

 

 

 

 

 

M

R

O

 

 

 

 

R

 

 

O

 

 

W

A

 

 

L

 

 

 

 

 

R

 

 

 

 

 

 

 

E

The thermostat controls the room temperature by turning either the compressor or electric heater on and off while the fan is running. Turn the thermostat control clockwise to provide a cooler room temperature; turn it counterclock- wise to provide a warmer one.

NOTE: If the fan cycle switch (see Additional Control Inputs) is in the CYCLE mode, both the compressor and fan will cycle on and off during the cooling modes.

OFF

 

OFF

 

LOW

FAN

HIGH

HEAT

FAN

ONLY

COOL

ONLY

 

 

HIGH

 

 

HEAT

LOW

MED

LOW

COOL

 

COOL

COOL

HIGH

 

 

 

 

COOL

HIGH COOL

This setting provides the most cooling output at the highest efficiency possible. In this mode the fan runs on high and the compressor cycles on and off.

 

OFF

HIGH

FAN

COOL

ONLY

MED

LOW

COOL

COOL

MEDIUM COOL

This setting provides quieter operation than High Cool. In this mode the fan runs at medium speed and the compres- sor cycles on and off.

OFF

 

OFF

 

LOW

FAN

HIGH

HEAT

FAN

ONLY

COOL

ONLY

 

 

HIGH

 

 

HEAT

LOW

MED

LOW

COOL

 

COOL

COOL

HIGH

 

 

 

 

COOL

LOW COOL

This setting dehumidifies the air and provides the quietest fan operation. In this mode the fan runs at the lowest speed and the compressor cycles on and off.

 

OFF

LOW

FAN

HEAT

ONLY

 

HIGH

HEATLOW

COOL

HIGH

COOL

HIGH HEAT

On high heat, the fan runs at its highest speed. In this mode the electric heater cycles on and off by thermostat.

6