Wiring

1.Remove the grille and filter from the front panel (Figure 10). Doing one side at a time, press the tab on the front panel (Figure 10) with one hand while lifting the grille with the other.

Figure 10

2.Using the four washer head sheet metal screws pro- vided, mount the front panel to the chassis through the front panel mounting holes (Figure 11).

Mounting

Holes

Mounting

Holes

Front

Chassis

Panel

 

Mounting

Holes

Figure 11

3.Reattach the filter and front grille. Place the supplied knobs onto the proper stem (Figure 12).

Knobs

Figure 12

IMPORTANT NOTES:

1.The unit is equipped with a rubber-grommet-mounted compressor. These grommets are factory set and require no adjustment.

2.Obstruction to air flow must be checked and removed. Check the indoor and outdoor grilles for obstructions. The unit must be located where curtains, furniture, trees, or other objects do not block air flow to and from the unit. If air is obstructed and/or deflected back into the unit, the air conditioner’s compressor may cycle on and off rapidly. This could cause damage to the compressor.

Wiring

Before wiring the unit, please review the following warnings and cautions.

Manual backgroundManual background WARNING

To avoid property damage, personal injury or death due to electrical shock, do not service this unit without first shutting off power to the unit from the circuit breaker and/or removing the unit cord set plug from the wall outlet.

Manual backgroundManual background WARNING

To avoid the risk of property damage, personal injury or electrical shock, do not use an extension cord with this unit.

Manual backgroundManual background WARNING

To avoid the risk of fire, property damage, or personal injury, use only copper conductors.

Manual backgroundManual background WARNING

To avoid the risk of personal injury, wiring to the unit must be properly polarized and grounded.