Maytag W10252706B Electrical Connection - U.S.A. Only, Power Supply Cord, Direct Wire, A B C

Models: W10252706B

1 16
Download 16 pages 15.21 Kb
Page 7
Image 7
Electrical Connection - U.S.A. Only

5.To mount anti-tip bracket to wood floor, drill two ¹⁄₈" (3.2 mm) holes at the positions marked on the bracket template. Remove template from floor.

To mount anti-tip bracket to concrete or ceramic floor, use a ³⁄₁₆" (4.8 mm) masonry drill bit to drill 2 holes at the positions marked on the bracket template. Remove template from floor. Tap plastic anchors into holes with a hammer.

6.Align anti-tip bracket holes with holes in floor. Fasten anti-tip bracket with screws provided.

Depending on the thickness of your flooring, longer screws may be necessary to anchor the bracket to the subfloor. Longer screws are available from your local hardware store.

Electrical Connection - U.S.A. Only

Power Supply Cord

Power Supply CordWARNING

Electrical Shock Hazard

Disconnect power before servicing.

Use a new 40 amp power supply cord.

Plug into a grounded outlet.

Failure to follow these instructions can result in death, fire, or electrical shock.

Direct Wire

Direct WireWARNING

Electrical Shock Hazard

Disconnect power before servicing.

Use 8 gauge copper or 6 gauge aluminum wire.

Electrically ground range.

Failure to follow these instructions can result in death, fire, or electrical shock.

1.Disconnect power.

2.Remove the terminal block cover screws located on the back of the range. Pull cover down and toward you to remove cover from range.

3.Remove plastic tag holding three 10-32 hex nuts from the middle post of the terminal block.

A

B

C

A. Two mounting tabs each side B. Terminal block cover

C. Hex-head screws