3.Feed the power supply cord through the strain relief on the cord/conduit plate on bottom of range. Allow enough slack to easily attach the wiring to the terminal block.

A 3-wire connection: Power Supply CordE. Neutral (center) wireD. Neutral (white) wireManual backgroundManual backgroundManual backgroundManual backgroundManual background

B

C

Manual backgroundD

A. Terminal block

B.Ground-link screw

C.UL listed strain relief

D.Power supply cord wires

4.Use a Phillips screwdriver to connect the green ground wire from the power supply cord to the range with the ground-link screw and ground-link section. The ground wire must be attached first.

5.Use ³⁄₈" nut driver to connect the neutral (white) wire to the center terminal block post with one of the 10–32 hex nuts.

3-wire connection: Power Supply Cord

Use this method only if local codes permit connecting chassis ground conductor to neutral wire of power supply cord.

1.Feed the power supply cord through the strain relief on the cord/conduit plate on bottom of range. Allow enough slack to easily attach the wiring to the terminal block.

A Manual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual background

B

C

Manual backgroundD

A. Terminal block

B.Ground-link screw

C.UL listed strain relief

D.Power supply cord wires - large opening

2.Use ³⁄₈" nut driver to connect the neutral (white) wire to the center terminal block post with one of the 10–32 hex nuts.

A

F

 

B

 

C

E

 

 

D

A. 10–32 hex nut

D. Green ground wire

B. Ground-link screw

E. Neutral (center) wire

C. Line 2 (red)

F. Line 1 (black)

6.Connect line 2 (red) and line 1 (black) wires to the outer terminal block posts with 10-32 hex nuts.

7.Securely tighten hex nuts.

NOTE: For power supply cord replacement, use only a power cord rated at 250 volts minimum, 40 amps or 50 amps that is marked for use with nominal 1³⁄₈" (3.5 cm) diameter connection opening, with ring terminals and marked for use with ranges.

8.Tighten strain relief screws.

9.Replace terminal block access cover.

A

E

 

B

D

 

C

 

A. 10–32 hex nut

D. Neutral (white) wire

B. Line 2 (red)

E. Line 1 (black)

C.Ground-link screw

3.Connect line 2 (red) and line 1 (black) wires to the outer terminal block posts with 10-32 hex nuts.

4.Securely tighten hex nuts.

NOTE: For power supply cord replacement, use only a power cord rated at 250 volts minimum, 40 amps or 50 amps that is marked for use with nominal 1³⁄₈" (3.5 cm) diameter connection opening, with ring terminals and marked for use with ranges.

5.Tighten strain relief screws.

6.Replace terminal block access cover.

9

Page 9
Image 9
Maytag W10252706B wire connection Power Supply Cord, A B C D, E. Neutral center wire, D. Neutral white wire