press the SETUP
Moving Magnet Cartridge Capacitance
The C500 allows the adjustment of the Moving Magnet Ca- pacitive Loading to accommodate a wide variety of car- tridge types and turntable/cabling combinations. The range of adjustment is from 50pf to 750pf in 50pf increments. To change the capacitance from the default value of 50pf set- ting perform the following steps:
1.Press the SETUP
2.Rotate the MENU Control until the Alphanumeric Dis- play indicates “MM 50 PF”. Refer to figure 50.
Figure 50
3.Rotate the SELECT 2 Control until the desired capaci- tance appears in the Display, e.g. “MM 150 PF”. Re- fer to figure 51.
Figure 51
4.If no other adjustments are to be made at this time, press the SETUP
Figure 52
tance appears in the Display, e.g. “MC 200 OHM”. Refer to figure 53.
4. If no other adjustments are to be made at this time,
Figure 53
press the SETUP
Passthru Mode
The C500 can be part of a Multichannel Sound System for SACD,
1.Press the SETUP
2.Rotate the MENU Control until the Alphanumeric Dis- play indicates “PASSTHRU OFF”. Refer to figure 54.
Moving Coil Cartridge Resistance
The C500 allows the adjustment of the Moving Coil Resis- tive Loading to accommodate a wide variety of cartridge types and turntable/cabling combinations. The range of ad- justment is from 25 ohms to 1,000 ohms in six increments. To change the resistive load from the default value of 25 ohms setting perform the following steps:
1.Press the SETUP
2.Rotate the MENU Control until the Alphanumeric Dis- play indicates “MC 25 OHM”. Refer to figure 52.
3.Rotate the SELECT 2 Control until the desired resis-
Figure 54
3.Rotate the SELECT 2 Control until the desired Input appears in the Display, e.g. “PASSTHRU CDR”. Re- fer to figure 55.
Figure 55
4.If no other adjustments are to be made at this time, press the SETUP