work-path

Work path – specifies a working directory that the translator uses for temporary storage, debug output etc for this translation type. The process must have write, file create and directory create access to this directory. Each translation in a configuration files must specify a different work path. Several subdirectories are created in the work path for use by the translator:.

stability-delay

Number of seconds to wait before rechecking the input path, when determining whether files are stable and ready for translation. This value is optional; if not supplied, the delay time specified in the command line (-t) is used. This argument is ignored unless –b is specified on the command line (that is, no translation delays are imposed in interactive mode).

For the input-path,output-pathand work-patharguments, it is assumed that a trailing path delimiter is not included in the path definitions. For example, on Win32 systems the user supplies

c:\trans\work

instead of

c:\trans\work\

Table 7-1 – Translation Formats

Name

Format

Read

Write

ADAC

ADAC (Pegasys)

Yes

Yes

 

 

 

 

DICOM

DICOM (ACR NEMA)

Yes

Yes

 

 

 

 

ECLIPSE

Eclipse

Yes

Yes

 

 

 

 

GE_ELSCINT_S

GE Elscint (SBACK)

Yes

Yes

 

 

 

 

GE_GENIE_D

GE Genie (DICOM)

Yes

 

 

 

 

 

GE_STARCAM

GE StarCam

Yes

 

 

 

 

 

NUMA

Numa (private)

Yes

Yes

 

 

 

 

PICKER

Marconi (Interfile)

Yes

Yes

 

 

 

 

SIEMENS

Siemens (ICON)

 

Yes

 

 

 

 

SMV_IF

SMV Interfile

Yes

Yes

 

 

 

 

SOPHA

Sopha (NXT/F83)

Yes

 

 

 

 

 

TOHSIBA_V

Toshiba (VI/DI)

Yes

 

 

 

 

 

For each translation type, the data flows from the specified input to the specified output path. There is no limit on the number of translation types that can be specified in a configuration file.