Mercury SR-10K Strike, Exit Request Door Contact, Reader and Interface Dimensions, Jumpersetting

Models: SR-10K SR-10K Mag-Stripe Access System

1 19
Download 19 pages 62.1 Kb
Page 18
Image 18
Reader and Interface Dimensions

5.5 [140]

2.0 [50]

1.3 [33]

2 X Ø0.18 [4.5]

HOLES

3.3 [84]

2.6 [66]

Reader and Interface Dimensions

3.25 [83]

 

1.4 [36]

2.9 [74]

Reader to Interface Connection:

Connect the Reader to the Interface Module using the straight 6-conductor modular cable. DO NOT use cross- over cable. Maximum distance between reader and interface is 500 feet using 22AWG wires.

6-COND.STRAIGHT

J2 Jumpers

NC Reader to Interface Connection:

C K1

NO Strike

NO

NC

C K2

+

12V GND

I2

I2

I1

I1

Strike

Forced Open,

Held Open

Alarm Buzzer

Exit Request

Door Contact

JUMPERSETTING

Typical Wiring Configuration

Communication Wiring: Maximum total cable length - 4,000 ft [1,200 m], 24 AWG

TO ADDITIONAL

SR−10K

SR−10K

SR−10K

PRINTER INTERFACE

 

 

(DISCONTINUED)

Set each interface to unique address. Install RS-485 termination jumper, J4, on the first and last units only.

Mercury Security Corporation, © 2005

SR-10K

Doc. 10107-0007 Rev 1.04

Page 18

Page 18
Image 18
Mercury SR-10K Strike, Exit Request Door Contact, Reader and Interface Dimensions, Reader to Interface Connection, SR−10K