Operating Mode 03:

Access Control and Alarm Panel Control

Description

The Access Control and Alarm Panel Control configuration provides for basic access control and gives some users the ability to send a pulse to arm and disarm alarm panels.

Both a downward and an upward read of all User Cards pulse Output K1, the strike control relay, to allow entry. In addition, the upward read of a Level 2 card pulses Output K2, allowing the momentary closure to simulate a key-switch input to an alarm panel.

User Level Specifications

User Level 1

Both downward and upward read will pulse Output K1.

User Level 2 (and 3)

A downward read will pulse Output K1

An upward read will pulse both Output K1 and Output K2.

Configuration

Input assignments:

Input I1 is connected to the armed/disarmed status output from the alarm panel.

Input I2 is connected to a “request to exit” button. Closing the contact initiates the request.

Upper LED assignment:

The upper LED follows Input I1, displaying the status of the alarm panel:

Open Contact is displayed as RED

Closed Contact is displayed as GREEN

Mercury Security Corporation, © 2005

SR-10K

Doc. 10107-0007 Rev 1.04

Page 12

Page 12
Image 12
Mercury SR-10K Mag-Stripe Access System manual Operating Mode Access Control and Alarm Panel Control

SR-10K, SR-10K Mag-Stripe Access System specifications

The Mercury SR-10K Mag-Stripe Access System is a cutting-edge access control solution designed for environments that require robust security and reliable performance. This system is well-suited for various applications, including commercial buildings, educational institutions, and industrial facilities. With its advanced technology and user-friendly design, the SR-10K provides a comprehensive security platform that streamlines access management.

One of the main features of the SR-10K is its compatibility with both magnetic stripe cards and ISO 7810-compliant cards. This flexibility allows organizations to implement existing card technologies without the need for extensive infrastructure changes. The system supports both single-door and multi-door configurations, making it adaptable to different facility requirements.

The SR-10K includes a powerful embedded controller that ensures efficient processing of access control transactions. This controller leverages smart technology to manage access rights and monitor activities in real-time, providing operators with immediate insights into system status. Additionally, it incorporates a user-friendly interface, allowing for straightforward programming and administration of the access control system.

Durability is a key characteristic of the SR-10K, as it is designed to withstand the rigors of everyday use in demanding environments. The system features weather-resistant components, making it suitable for both indoor and outdoor installations. This robustness contributes to the overall reliability of the security solution, reducing maintenance and operational costs over time.

The SR-10K also integrates seamlessly with existing security infrastructures, supporting various communication protocols such as Wiegand and RS-485. This connectivity allows organizations to enhance their security measures by integrating the access control system with surveillance cameras, alarms, and other security devices. The SR-10K can be easily scaled to accommodate future growth, ensuring that the system remains effective as security needs evolve.

In addition to its technical features, the SR-10K prioritizes user experience. The system offers intuitive software for system management, which simplifies the process of managing user profiles, access permissions, and activity logs. This accessibility ensures that security personnel can effectively monitor and respond to access events.

Overall, the Mercury SR-10K Mag-Stripe Access System stands out as a versatile and reliable access control solution. Its combination of advanced features, robust construction, and ease of use makes it an ideal choice for organizations seeking to enhance their security while maintaining operational efficiency.