Configuration Settings (Commands 31through 34)

Configuration Settings (Commands 31through 34)

Command 31 - Set the Door Held Open Time

*Command 31 - Set the Door Held Open TimeCommand 42 - Copy the Cipher Database only 3 Command 43 - Copy the Card Database onlyManual background 1 0-9 Manual backgroundManual background 0-9

-select Command 31 (from door opening to held open alarm)

-select the held open time: 00 to 99 seconds

Command 32 - Set the Door Strike Relay Pulse Time (Output K1)

*Manual backgroundManual background3 Manual backgroundManual background2 0-9 Manual backgroundManual background 0-9

-select Command 32

-select the strike pulse time: 00 to 99 seconds (+1/2 second)

Command 33 - Set the Auxiliary Relay Pulse Time (Output K2)

*Manual backgroundManual background 3 Manual backgroundManual background 3 0-9 Manual backgroundManual background 0-9

-select Command 33

-select the pulse time for Output K2: 00 to 99 seconds (+1/2 second)

Command 34 - Set the Auxiliary Relay's Pulse Time (Output K2)

*Manual backgroundManual background3 Manual backgroundManual background4 1 or 2

-select Command 34

-select the pulse type: 1 for normal, 2 for intermittent output

Configuration and Database Copy Commands (Commands 41through 44)

The following commands allow the configuration and database to be copied from one SR-10K to another SR-10K. These commands transfer the selected database elements from the SR-10K where the command is being entered to the SR-10K whose address is specified in the command.

The SR-10K addresses are set by installing the jumper pattern for the desired address on the Inter- face Module as shown on the installation diagram.

The color of the upper LED is set to flashing amber for the duration of the the data transfer. Periodic short beeps are used by longer transfers to indicate "transfer in progress". The transfer of the entire "block mode" card database (1,600 users) may take up to 1 minute.

The completion of a succesful transfer is indicated with the "long-beep". A transfer error condition is signalled with three short beeps along with a red flash on the upper LED. A transfer error is caused by either incorrect wiring, or by incorrect jumper settings. Notice: the transfer commands are not 'broadcast'; each SR10K must be set to a unique address 0 to 15.

Command 41 - Copy the Configuration settings only - no card or cipher databases

*Manual backgroundManual background 4 Manual backgroundManual background1 0-9 Manual backgroundManual background 0-9

-select Command 41 (copies seetings enterd with commands 31-34, and 91-95)

-select the address of the SR-10K to copy the data to - 00 to 15

Command 42 - Copy the Cipher Database only

*Manual backgroundManual background 4 Manual backgroundManual background 2 0-9 Manual backgroundManual background 0-9

-select Command 42 - copies cipher users 0 through 9

-select the address of the SR-10K to copy the data to - 00 to 15

Command 43 - Copy the Card Database only

*Manual backgroundManual background 4 Manual backgroundManual background 3 0-9 Manual backgroundManual background 0-9

-select Command 43 - copies users 00 through 99, or through 1599

-select the address of the SR-10K to copy the data to - 00 to 15

Command 44 - Copy ALL: Configuration Settings, Card and Cipher databases

*Manual backgroundManual background 4 Manual backgroundManual background 4 0-9 Manual backgroundManual background 0-9

-select Command 44 - combines Commands 41, 42, and 43

-select the address of the SR-10K to copy the data to - 00 to 15