may also invalidate this guarantee. Labour and carriage charges are not covered unless by local agreement.
Outside the UK, local warranty liability is restricted to equipment purchased within the territory. Our agents abroad are only under contractual obligation to service under guarantee equipment sold through them. They are entitled to make a
ABOUT THE PRODUCT
The C51 powers 200 and 300 Series Remote Active installation loudspeakers.
It features active
Ten channels of approximately100W into
8Ω (160W into 4Ω) RMS amplification are provided, grouped into five pairs, each providing bass and tweeter outputs from a
The crossovers take the form of
Thermal,
The front panel includes five sockets for installation of the crossover cards, which can be accessed by unscrewing the transparent smoked access cover.
The rear panel is divided into five channel pairs identified as HF (tweeter) and LF (bass). A single
In addition to the power input socket and power switch, the rear panel also offers a 3.5mm jack socket for connection of an industry standard trigger input
C51 Powered Crossover/Amplifier
Output power | 10 channels of 100W into 8Ω |
| / 160W into 4Ω, arranged in |
| 5 x HF/LF pairs sourced from |
| |
| module |
Frequency response
Output impedance | |
THD+Noise | Typical: 0.1% @ 60W output, |
| 0.008% @ 1W |
5 x Mono unbalanced (phono) | |
| impedance 10 kΩ |
| 5 x Mono balanced (XLR3F) |
| impedance 20 kΩ/leg |
| |
| balanced and unbalanced |
Outputs | LF and HF pairs of |
| binding posts per channel pair |
Other connections | 12vdc, 5W Temperature |
| controlled fan output (3.5mm |
| jack) |
| |
| (3.5mm jack) |
Controls | |
| unbalanced input switch per |
| input. |
| Rear panel main power |
| switch. |
6