ENGLISH

„Command and data

Operating command and data (Binary code)

Command

Type

 

 

Data description

 

 

 

0000

Connection check

Checks whether communication is available between this unit and

the PC during standby.

 

 

 

 

 

 

 

 

During standby

 

5057

Power supply

31

: Turns on the power.

During power on

 

 

 

 

 

 

30

: Turns off the power. (Standby mode)

 

 

 

 

 

 

During power on

 

 

 

30

: S-VIDEO

 

4950

Input

31

: VIDEO

 

32

: COMP.

 

 

 

 

 

 

36

: HDMI 1

 

 

 

37

: HDMI 2

 

 

 

 

 

 

 

During power on

 

 

 

30

: Switches to “Normal”.

4754

Gamma table

31

: Switches to “Theater1”.

32

: Switches to “Theater2”.

 

 

 

 

33

: Switches to “Dynamic”.

 

 

34

: Switches to “Custom”.

 

 

 

 

 

 

 

30

: 1.8

35 : 2.3

 

 

31

: 1.9

36 : 2.4

4750

Gamma coefficient

32 : 2.0

37 : 2.5

 

 

33

: 2.1

38 : 2.6

 

 

34

: 2.2

 

 

 

 

4752

Gamma data (R)

Sets the gradation (0 ~ 1023) of the output signal in hexadecimal.

The data is 16 bit (2 byte) with the 2 byte data in the high/low order.

 

 

 

 

 

4747

Gamma data (G)

Same as gamma data (R).

 

 

 

4742

Gamma data (B)

Same as gamma data (R).

 

 

 

 

 

 

During power on

 

5453

Test pattern

30 : Do not display.

 

 

 

36

: Displays staircase (gray).

 

 

 

5243

Remote Control

Sends the same code as the supplied remote control.

z“Remote control code” (pP47)

 

 

 

 

 

 

 

Getting Started

Preparation

Basic Operation

Settings

Troubleshooting

Others

45

Page 45
Image 45
Meridian Audio MF-10 manual Video Comp