We will now address each of the above eight requirements in detail:

1. Installing the Air Conditioner Unit:

AIR CONDITIONER DIMENSIONS

UNIT BTU

WIDTH

LENGTH

HEIGHT

5,200

Cool Only

11.5 Inches

15 Inches

11.5 Inches

5,200

Reverse Cycle

12 Inches

18 Inches

11.5 Inches

6,500

 

11.5 Inches

16 Inches

11.5 Inches

9,000

 

11.5 Inches

16 Inches

11.5 Inches

12,000

13 Inches

19.75 Inches

13.75 Inches

16,500

13.5 Inches

19.75 Inches

13.75 Inches

24,000

17 Inches

23 Inches

13.75 Inches

The air conditioner needs to be mounted in an area where it will physically fit, as well as accommodate a properly sized return air grill and any ducting or splitters (Wyes) which would be attached to the air output collar. In addition, you need to insure there is space for the water hoses to be connected.

The air conditioner must be securely mounted on a flat surface. If the sole of the boat (cabin floor) cannot accommodate the size of the air conditioner base plate, a mounting shelf or platform must be built. Typically the shelf will be made from 3/4 inch marine grade plywood which can be either fiberglassed or mechanically attached to the boat’s sole or superstructure. Never screw directly into the hull.

When attaching the unit to the sole of the boat, the superstructure or a fabricated mounting shelf, always make absolutely positive that the length of the screws being used to mount the unit will not engage the hull. If there is any question as to whether the hull may be compromised, an alternative mounting method must be used or another mounting spot must be located.

The electrical box, unlike the air conditioner, can be mounted in any attitude. It is attached to the air conditioner by a detachable 40 inch electrical cable allowing it to be mounted above the unit, on a side wall or bulkhead and, if needed, in a totally inverted position.

IMPORTANT

IT IS NOT UNCOMMON IN AIR CONDITIONING SYSTEMS FOR CONDENSATION LINES OR PANS TO BECOME BLOCKED OVER PROLONGED USE. WHEN SELECTING THE ELECTRICAL BOX MOUNTING SPOT MAKE SURE THAT IT IS NOT LOCATED WHERE