InstallationRisk of electric shock!
The dry-running sensor must be installed such that sensor enclosure, power supply cable and plug cannot get wet under any operating condition.
If there is a risk of the discharge line, with the dry-running sensor installed, falling into water, it must be properly secured (e.g. with piping clips).
Install the dry-running sensor so that the sensor enclosure, power supply cable and plug cannot be flooded when the pump is started.
1.Install the tee fitting in the discharge line (=behind the pump). The flow direction is irrelevant.
2.In order for the dry-running sensor to shut down the pump as early as possible, the distance bet- ween pump and tee fitting should be as short as possible (but with sufficient distance to any water!).
3.Screw sensor enclosure into tee fitting.
4.Plug dry-running sensor into a properly installed and earthed outlet. The plug must remain accessi- ble at all times, so it can be disconnected imme- diately from the power supply in case of a fault.
5.Plug pump into the dry-running sensor’s female connector.