INSTALL CIRCULATING BLOWER

THERMOCOUPLE WIRE

INSTALL ALL CONTROL

AND HANDLE KNOBS

KNOCKOUT IN DRAFT

CHANNEL REMOVED

FORCED DRAFT

BLOWER

FIGURE 20 INSTALL COMFORT CONTROL CENTER AND FORCED DRAFT BLOWER

COMFORT CONTROL CENTER

FAN/LIMIT CONTROL

SECURE CONDUIT WITH CONDUIT CLAMPS AND #10 SHEET METAL SCREW

PRE-WIRED FLEXIBLE CONDUIT TO CIRCULATING BLOWER

INSTALL CIRCULATING BLOWER

The flanges on the circulating blower simply slide be- hind the angle mounts welded to the rear of the furnace. Slide in from the top side, figure 21.

INSTALL FILTER BOX

The filter box is standard on Model 526. Installation in- structions are included with Model 526 filter box.

1.The filter box can be installed with the filter on either side. The access door will fit the opening either side and the handle should face forward.

2.Find two factory shipped support angles. Force sup- port angle sides without tabs into the groove of the mounting strip on both rear sides of the furnace. Posi- tion at correct height to accept filter box, figure 21.

3.With filter box set against back of furnace, bend down the tabs on the support angles so they lock be- hind the flanges of the top and bottom panels of the box.

4.Install the access door. Install filter not supplied and install a cold air return system to the filter box fil- ter side opening.

5.Route flexible conduit from comfort control through hole in top panel and to box connector on blower connection box. Connect wires to blower motor by joining wires of the same color.

FEED

MOTOR

White

White/Purple

Red

Red

Blue

Blue

Black

Black

24