FIGURE 5 WOODCHUCK CONTROLS

DOUBLE LATCH

 

 

COMFORT

LOADING DOOR

COMFORT

HEAT EXCHANGER

CONTROL CENTER

 

CONTROL ROD

 

 

CONTROL CENTER

 

 

 

 

SHAKER

 

 

 

GRATE

 

 

FAN/LIMIT

 

 

 

 

FAN/LIMIT

 

 

 

DOUBLE LATCH

 

 

 

LOADING DOOR

 

DRAFT CHANNEL

 

MANUAL DRAFT

 

SELECTOR - 80/20

 

 

 

(Forced Draft Is

 

COMBUSTION AIR

 

 

 

Optional)

 

RATIO CONTROL

 

MODEL 526

 

 

 

MODELS

 

 

 

2900/4000

ASH DOOR

 

ASH DOOR

 

 

 

 

 

 

FORCED DRAFT

 

SHAKER GRATE CRANK.

 

BLOWER

 

SHAKER GRATES ARE OPTIONAL

FIGURE 5 WOODCHUCK CONTROLS

CIRCULATING

BLOWER

DRAFT BLOWER

DRAFT BLOWER

MANUAL SWITCH

LO-LIMIT BYPASS

 

FIGURE 6 COMFORT CONTROL CENTER

OPERATING YOUR WOODCHUCK

FURNACE

STARTUP

Never leave ash pan in unit. Use only when cleaning out ashes.

First thing is to check that your main blower and draft blower are in proper working order before lighting a fire. To check main blower, push button on fan/limit control for manual override testing. When finished, reset to au- tomatic position, figure 5. Next, turn thermostat upstairs to high temperature so draft blower turns on.

NOTE: All models are equipped with a “low limit” which will not allow the auto draft to operate when the unit is not warm. To start auto draft, turn Lo-Limit toggle switch on comfort control center to “On”, figure 6.

Now you are ready to light a fire.

BURNING WOOD IN YOUR WOOD- CHUCK

1.Adjust draft channel selector, figure 5, to appropriate fuel setting on model 2900/4000. On Model 526 with manual draft, open it. Place several pieces of crumpled paper in the center of your Woodchuck. Criss-cross a couple of handfuls of dry kindling wood 3/4" thickness, then several small dry pieces of firewood. Ignite the pa- per and close the door. Do not attempt to open the door immediately after igniting the fire. There could be a flame flash out.

2.It will take 5-10 minutes for the fire to establish itself. Once you have some good red hot burning embers, add larger pieces of wood. All chimneys and hookups are different. After 3-4 fires, you’ll find out how your unit works for the best starting.

3.After about 30-40 minutes you can adjust the draft according to your needs. Adjust smoke pipe damper ac- cording to your needs also.

NOTE: On airtight units, the burning time is controlled mostly by the draft controls on the furnace, contrary to