PROBLEM

POSSIBLE CAUSE

SOLUTION

9. Excessive amounts of

Improper draft.

Measure with draft gauge-should

smoke coming out loading

 

have .04 to .06 water column.

door when loading.

Chimney cap too close to top of chimney.

Relocate.

 

Too long of run of smoke pipe from Woodchuck

Relocate Woodchuck closer to

 

to chimney.

chimney.

10. Puffing of smoke

Improper draft.

Check draft with gauge. Should be

through draft control.

 

.04 to .06 water column.

 

Down draft on chimney.

Check for cold spots on chimney

 

 

or obstruction outside chimney.

 

 

Trees or other buildings.

 

Plugged chimney.

Check with mirror in clean-out

 

 

door or send cleaning brush down

 

 

chimney. Check stovepipe con-

 

 

nections.

11. Excessive dirt build-up

Too much smoke escaping out of loading door

Check problem No. 9.

around air vent in home.

when loading.

 

 

Bad weld in fire box of unit.

Call dealer immediately.

 

No return air ducting.

Install return air duct.

12. Improper seal around

Door rope not sealing on door frame.

Check door rope so that all parts

door.

 

of door frame are sealed, espe-

 

 

cially corners.

 

Loose door from shipment.

Simply bend door latch in to

 

 

tighten door seal.

13. Excessive creosote

The use of wet, frozen, or unseasoned wood.

If you have to use wet wood, make

build-up.

 

loads smaller and burn them hotter.

 

The use of soft wood, particularly those of high resin

Avoid using if possible.

A reminder, whatever kind of

content such as plywood or blandex with glue.

 

fuel you burn, there is some

Poor natural draft or an obstruction in the stove

Measure draft with gauge. Should

kind of residue build-up on

pipe or chimney flue.

have a minimum of .04-.06 water

the furnace and chimney.

 

columns of draft.

Same with wood no matter

Too long of burning times.

Smaller and hotter fires.

how good the conditions.

Inadequate amount of oxygen supplied to the

Adjust draft for hotter fires or in

 

combustion chamber

some homes, it has been deter-

 

 

mined there was not enough in the

 

 

basement due to such an air-tight

 

 

home. We recommend 4" round

 

 

hole to the outside with a screen

 

 

on to keep varmints out.

 

Low fire or flue gas temperatures.

Smaller loads of wood and hotter

 

 

fire. Stack temps. should maintain

 

 

minimum 300° to 400°.

 

Uninsulated stovepipe or chimney flues, espe-

Never use uninsulated pipe for

 

cially if construction is exterior to the house.

chimneys installed on the outside

 

 

of the house, INSULATE!

 

Air leaks in the stove pipe or chimney.

Check chimney from top to bot-

 

 

tom. NOTE: Creosote is a tarry liq-

 

 

uid or solid coming from distillation

 

 

of wood during the combustion

 

 

process. The heavier buildups, the

 

 

greater chance of a chimney fire.

 

 

NOTE: No matter how seasoned

 

 

the wood, no matter how good the

 

 

draft, you always will get a small

 

 

amount of soot buildup. Should be

 

 

cleaned before winter firing and

 

 

during mid-winter’s firing.

 

 

 

14