MicroBoards Technology Premium Pro Series user manual Write ERROR-RECOVERED with Auto Reallocation

Models: Premium Pro Series

1 23
Download 23 pages 43.55 Kb
Page 19
Image 19

DVD Premium Pro Series

MICROBOARDS TECHNOLOGY, LLC

 

 

 

WRITE ERROR-RECOVERED WITH AUTO REALLOCATION

 

0C

02

 

0C

03

WRITE ERROR-RECOMMEND REASSIGNMENT

 

0C

07

WRITE ERROR-RECOVERY NEEDED

 

0C

08

WRITE ERROR-RECOVERY FAILED

 

0C

09

WRITE ERROR-LOSS OF STREAMING

 

0C

0A

WRITE ERROR-PADDING BLOCKS ADDED

 

11

00

UNRECOVERED READ ERROR

 

11

06

CIRC UNRECOVERED ERROR

 

15

00

RANDOM POSITIONING ERROR

 

15

01

MECHANICAL POSITIONING ERROR

 

15

02

POSITIONING ERROR DETECTED BY READ OF MEDIUM

 

16

00

DATA SYNCHRONIZATION MARK ERROR

 

16

01

DATA SYNC ERROR-DATA REWRITTEN

 

16

02

DATA SYNC ERROR-RECOMMEND REWRITE

 

16

03

DATA SYNC ERROR-DATA ATUO-REALLOCATED

1604 DATA SYNC ERROR-RECOMMEND REASSIGNMENT

1700 RECOVERED DATA WITH NO ERROR CORRECTION APPLIED

17

01

RECOVERED DATA WITH RETRIES

17

02

RECOVERED DATA WITH POSITIVE HEAD OFFSET

17

03

RECOVERED DATA WITH NEGATIVE HEAD OFFSET

17

04

RECOVERED DATA WITH RETRIES AND/OR CIRC APPLIED

17

05

RECOVERED DATA USING PREVIOUS SECTOR ID

17

06

RECOVERED DATA WITHOUT ECC - DATA AUTO-REALLOCATED

17

07

RECOVERED DATA WITHOUT ECC - RECOMMEND REASSIGNMENT

17

08

RECOVERED DATA WITHOUT ECC - RECOMMEND REWRITE

1709 RECOVERED DATA WITHOUT ECC - DATA REWRITTEN

1800 RECOVERED DATA WITH ERROR CORRECTION APPLIED

18

01

RECOVERED DATA WITH ERROR CORR. & RETRIES APPLIED

18

02

RECOVERED DATA - DATA AUTO-REALLOCATED

18

03

RECOVERED DATA WITH CIRC

18

04

RECOVERED DATA WITH L-EC

18

05

RECOVERED DATA - RECOMMEND REASSIGNMENT

18

06

RECOVERED DATA - RECOMMEND REWRITE

1807 RECOVERED DATA WITH ECC - DATA REWRITTEN

1900 DEFECT LIST NOT ERROR

19

01

DEFECT LIST NOT AVAILABLE

19

02

DEFECT LIST ERROR IN PRIMARY LIST

19

03

DEFECT LIST ERROR IN GROWN LIST

1A

00

PARAMETER LIST LENGTH ERROR

1B

00

SYNCHRONOUS DATA TRANSFER ERROR

1C

00

DEFECT LIST NOT FOUND

1C

01

PRIMARY DEFECT LIST NOT FOUND

1C

02

GROWN DEFECT LIST NOT FOUND

1D

00

MISCOMPARE DURING VERIFY OPERATION

2000 INVALID COMMAND OPERATION CODE

2100 LOGICAL BLOCK ADDRESS OUT OF RANGE

21

02

INVALID ADDRESS FOR WRITE

2400 INVALID FIELD IN CDB

2500 LOGICAL UNIT NOT SUPPORTED

2600 INVALID FIELD IN PARAMETER LIST

26

01

PARAMETER NOT SUPPORTED

26

02

PARAMETER VALUE INVALID

26

03

THRESHOLD PARAMETERS NOT SUPPORTED

2604 INVALID RELEASE OF ACTIVE PERSISTENT RESERVATION

2700 WRITE PROTECTED

27

01

HARDWARE WRITE PROTECTED

27

02

LOGICAL UNIT SOFTWARE WRITE PROTECTED

27

03

ASSOCIATED WRITE PROTECT

27

04

PERSISTENT WRITE PROTECT

27

05

PERSISTENT WRITE PROTECT

2706 CONDITIONAL WRITE PROTECT

2800 NOT READY TO READY CHANGE, MEDIUM MAY HAVE CHANGED

19

Page 19
Image 19