UTILITY ROUGH-IN DIMENSIONS AND POSITIONING

SECTION 2

INSTALLATION

UTILITY ROUGH-IN DIMENSIONS AND POSITIONING

FOR PS624-SERIES OVENS

WARNING

DO NOT USE CONDUIT FOR

GROUND CONNECTION.

CAUTION

IT IS RECOMMENDED THAT THE OVEN BE PLACED UNDER A VENTILATION HOOD FOR ADEQUATE AIR SUPPLY AND VENTILATION.

ELECTRIC SUPPLY TO BE

PROVIDED BY CUSTOMER

/.

/&&

4OO/VEN DO NOT USE CONDUIT FOR



MM

/.

/&&

4OO/VEN ELECTRIC SUPPLY TO BE



MM

Suggested dimensions are shown; utility code

3UGGESTEDEDIMENSIONS ARE SHOWN UTILITY CODEO

REQUIREMENTSrequirementsSUPERSEDEsupersedeANYanyFACTORSfactorsSHOWNshown .

CIRCUITBREAKER

A seperate circuit breaker with lockout/tagout electrical shutoff is required for each, seperately wired oven.

See breaker sizing requirements below:

ELECTRICAL SPECIFICATIONS

NOTE: Please refer to page 2, Electrical Specifications chart and your units data plate information, for more detailed information.

DOMESTIC: 208V, 60 Hz, 14.4 kW, 50A Service

240V, 60 Hz, 14.4 kW, 50A Service

480V, 60 Hz, 17.4 kW, 30A Service

Do NOT use conduit for ground.

or

EXPORT: CE MODEL

208V, 50/60 Hz, 14.4 kW, 50A Service

230-240V, 50/60Hz, 13.2/14.4 kW, 50A Service

380V, 50/60 Hz, 17.4 kW, 25A Service

Do NOT use conduit for ground.

POWER RATING

14.4kW Standard

17.4kW Optional

Figure 2-9. Typical PS624-Series Oven(s)

Installation

SUPPLY WIRE

Supply wire size must be in accordance with the National Electrical Code (current edition) and must be in compliance with local codes.

SUGGESTED

If space permits, service should be located near the control console end of the oven(s) to allow convenient access to safety switches.

II. VENTILATION GUIDELINES

Use of a ventilation hood is not required for proper operation, but installation must conform with all local codes and regulations.

Local codes and conditions vary greatly from one area to another and must be complied with. Following are the suggested requirements for good ventilation. Please re- member these are recommendations or guidelines, you may have a special condition or problem that will require the services of a ventilation engineer or specialist. Proper ventilation is the oven owner’s responsibility. Improper ventilation can inhibit oven performance.