II.COMPONENT INFORMATION AND LOCATION (Figures 3-1 and 3-2)

SECTION 3

OPERATION

II.COMPONENT INFORMATION AND LOCATION (Figures 3-1 and 3-2)

A. Door Safety Switch

The Door Safety Switch is located at the lower right side of control panel opening. Opening the control panel door permits this switch to open, disconnecting power to all electrical controls, except for the blower motor inverters, located in the left side control cabinet.

CAUTION

Do NOT touch the wires going to this safety switch. Current is always present.

B. Blower Switch

The blower switch has two positions. The switch must be “ON” or “I” for the main blowers to come on and permit the oven to run. The fan circulates the air throughout the oven and must stay on during baking and during the cool down cycle above 200°F (93°C) to prevent blower

bearing damage. To protect the blower motor and bearings a thermostatic override is built into the oven. If the temperature inside the oven is over 200°F (93°C) the main blower will continue to run after the blower switch is turned to the “OFF” or “O” position.

C. Heat / Conveyor Switch

The “Heat/Conveyor Switch” allows the heat to come on. Activation is determined by the settings on the Digital Temperature Controller.

D. Temperature Controller

The temperature controller is a solid-state, PID type to maintain the operator-set temperature. The temperature controller continuously monitors the oven temperature and turns on the modulating solid state relay controller. The heat is proportioned as required to maintain a constant oven temperature.

The temperature controller contains a low-limit switch which allows the oven to cool down to 200°F (93°C) before shutting off the blower. A high-limit indication (ALM 1) will appear on the display if the oven reaches 650°F (343°C).

#ONVEYOR 0OWER 4RANSFORMER

#OOLINGL&AN

4EMPERATUREU

#ONTROL

#ONVEYOR 3PEED

#ONTROLT"OARD

#IRCUITC"REAKERS

"LOWER-AIN-

3WITCH

(EAT#ONVEYOR

3WITCH

(I,O"LOWER 3PEEDE2ELAY

#ONVEYOR

(IGH ,IMIT

(IGH ,IMIT

$ISC

'EARMOTOR

4HERMOSTAT

2ESET

4HERMOSTAT

Figure 3-2. Interior View of Control Console