SECTION 2
INSTALLATION
III.ELECTRICAL CONNECTION INFORMATION FOR
WARNING
Authorized supplier personnel normally ac- complish the connections for the ventilation system, electric and gas supplies, as ar- ranged by the customer. Following these connections, the
Check the oven data plate (Figure
NOTE: The electric supply installation must satisfy the requirements of the appropriate statutory authority, such as the National Electrical Code (NEC), ANSI/NFPA70, (U.S.A.); the Canadian Electrical Code, CSA C22.2; the Australian Code AG601; or other applicable regulations.
A fused disconnect switch or a main circuit breaker (customer furnished) MUST be installed in the electric supply line for each oven; it is recommended that this switch/ circuit breaker have lockout/tagout capability. The electric supply connection must meet all national and local electrical code requirements. Copper is the recommended material for the electrical supply conductors.
IV. ELECTRIC SUPPLY
Electrical connection is made through a cord and plug. A cord, plug and strain relief is supplied for Domestic oven models, only. International ovens must supply, See Electrical Specifications chart on page 2.
The supply conductors must be of the size and material (copper) recommended to provide the cur- rent required; (refer to the data plate for the ampere specifications). The power cord plug must not be altered in any manner. Do not remove the grounding prong from the electrical plug supplied, as this can cause an unsafe operating condition.
ELECTRICAL
INLET
Figure 2-11. Junction Connection Box
International CE Plate | Domestic Plate |
Figure 2-10. Typical Electric Oven Data Plate
14