Installation of several appliances
When installing two or more appliances next to each other a spacer bar b must be used between each one.
See "Fixing the spring clamps and spacer bars".
Worktop cut-out - two appliances
Worktop cut-out
- three appliances
To calculate the cut-out width (D) required:
Add up the widths of each appliance (e.g. width A + B + C etc.) and subtract 16 mm from this figure
(i.e. 8 mm is taken off either end of the appliance run).
Number of | Appliance width in mm | Worktop | ||||
appliances |
|
|
|
|
|
|
1 | 288 | 288 | - 16 = 272 |
|
| |
|
|
|
|
|
|
|
2 | 288, 288 | 288 | + 288 | - 16 | = 560 |
|
|
|
|
|
|
|
|
2 | 288, 380 | 288 | + 380 | - 16 | = 652 |
|
|
|
|
|
|
| |
3 | 288, 288, 288 | 288 | + 288 | + 288 - 16 | = 848 | |
|
|
|
|
|
| |
3 | 288, 288, 380 | 288 | + 288 | + 380 - 16 | = 940 | |
|
|
|
|
|
|
|
32