Electrical connection
Electrical connection of the appliance should be made by a qualified electri- cian and in accordance with local and national standards.
Note to installer:
Please leave these instructions with the consumer.
Power supply:
Please check dataplate for 240 VAC; 60 Hz or
208 VAC; 60 Hz
Caution:
Disconnect the power supply be- fore servicing. To reduce the risk of electric shock, make sure that the appliance is properly grounded after installation.
WARNING:
THIS APPLIANCE MUST BE GROUNDED
For CDN only
The appliances are provided with 3 ter- minal leads: 1 black wire, 1 red wire and 1 green wire which have to be con- nected to a separate overcurrent pro- tection device (Miele fuse box).
All hot wires (black and red) have to be fused individually before connecting them to the main power supply leads.
Use 15 A / 250 V fuses for ap- pliances rated 240 VAC.
Connect black terminal wire to L1 (black) and red terminal wire to L 2 (red). The green terminal wire (ground) has to be connected directly to the equivalent colored power supply leads.
All connections must be done in a proper way.
SEE ALSO WIRING DIAGRAM PRO- VIDED WITH THE APPLIANCE.
For USA only
The appliance is provided with 3 termi- nal leads, 1 black wire (L 1), 1 red wire (L 2) and 1 green wire (GND) which have to be connected to a dedicated junction box. Connect black wire to L1, red wire to L2 and green wire to GND.
All connections must be done according to code.
SEE THE CIRCUIT DIAGRAM PRO- VIDED WITH THE APPLIANCE.