Installation instructions
There must be a minimum distance of 1- 3/16" (30 mm) between the cooktop and adjacent cabinet or tall appliance.
2 3/16’’ |
19 5/16’’ |
2 3/16’’ |
Prepare the countertop cut-out as il- lustrated.
Dimension ”B“ will change depend- ing on how many combisets are installed and is given on the chart.
| Depth | Width | Width |
| in | (Dimen- | (Dimensio |
| mm * | sion B) | n B) in |
|
| in mm | inches |
|
|
|
|
2 zone Combiset |
|
|
|
1 appliance | 490 | 265 | |
2 appliances | 490 | 558 | 22" |
3 appliances | 490 | 851 | |
4 appliances | 490 | 1144 | |
5 appliances | 490 | 1437 | |
|
|
|
|
4 zone Combiset |
|
|
|
1 appliance | 490 | 560 | |
2 appliances | 490 | 1143 | 45" |
3 appliances | 490 | 1728 | |
|
|
|
|
Combination |
|
|
|
One 2 zone |
|
|
|
+ one 4 zone | 490 | 851 | |
Two 2 zone |
|
|
|
+ one 4 zone | 490 | 1143 | 45" |
Three 2 zone |
|
|
|
+ one 4 zone | 490 | 1437 | |
One 2 zone |
|
|
|
+ two 4 zone | 490 | 1436 | |
Two 2 zone |
|
|
|
+ two 4 zone | 490 | 1729 | |
|
|
|
|
Extractor (e.g. DA 8-2)
For installation between two appliances:
- Dimension B increases by 90 mm (3 9/16").
For installation at the end of a combination:
-Dimension B increases by 98 mm (3 7/8").
*490 mm = 19 5/16 "
22