Installation and electrical connection
All electrical work should be carried out by a competent person, in accordance with national and local safety regula- tions.
The microwave oven is supplied with a mains cable and plug for connection to a single phase
If the cable is damaged it must be replaced by a special cable which must be fitted by a competent per- son trained by the manufacturer.
Please consult the Customer Ser- vice dept.
For extra safety it is advisable to install a residual current device (RCD) with a trip current of 30 mA.
GB / IRL
Connection should be made via a fused connection unit or a fused plug and a suitable switched socket, (rated load under 3000 W), or via suitable iso- lator (rated load over 3000 W), which is easily accessible.
AUS / NZ
The plug rating is 10 A.
This appliance is elecrically sup- pressed according to
AS / NZS 4052 : 1992
Important
The wires in the mains lead are col- oured in accordance with the following code:
Green/yellow = earth
Blue = neutral
Brown = live
As the colours of the wires in the mains lead of this appliance may not corre- spond with the coloured markings ident- ifying the terminals in your plug, pro- ceed as follows:
The wire which is coloured green and yellow must be connected to the termi- nal in the plug which is marked with the letter E or by the earth symbol zor coloured green or green and yellow.
The wire which is coloured blue must be connected to the terminal which is marked with the letter N or coloured black.
The wire which is coloured brown must be connected to the terminal which is marked with the letter L (GB / IRL) or A (AUS / NZ) or coloured red.
WARNING
THIS APPLIANCE MUST
BE EARTHED
37