Installation

Electrical connection

This tumble dryer is supplied ready for connection to an a.c. single phase sup- ply. The machine is supplied with a 2 m long mains cable with moulded plug.

The appliance should be connected up only by a qualified electrician, in accor- dance with national and local safety regulations.

For extra safety it is advisable to install a residual current device (RCD) with a trip current of 30 mA.

The voltage, rated load and plug rating are given on the data plate. Please en- sure that these match the household mains supply.

Important

The wires in the mains lead are col- oured in accordance with the following code:

Green/yellow = earth

Blue = neutral

Brown = live

As the colours of the wires in the mains lead of this appliance may not corre- spond with the coloured markings iden- tifying the terminals in your plug, pro- ceed as follows:

The wire which is coloured green and yellow must be connected to the termi- nal in the plug which is marked with the letter E or by the earth symbol z or coloured green or green and yellow.

The wire which is coloured blue must be connected to the terminal which is marked with the letter N or coloured black.

The wire which is coloured brown must be connected to the terminal which is marked with the letter A or coloured red.

WARNING

THIS APPLIANCE MUST BE

EARTHED

27