Miele T 220 Venting systems overview, Venting system with Flexible ducting hose

Models: T 220

1 44
Download 44 pages 26.86 Kb
Page 31
Image 31

Installation - venting

Venting systems overview

The various venting systems which are possible are described on the following pages. These include:

aFlexible ducting hose

bPlastic piping or galvanised steel piping

cConnecting directly to the wall vent

dMain venting duct

A ring adapter** (1) is installed in adapter (2) for the installation of a flexi- ble vent duct. It reduces time and en- ergy requirements during drying when used in combination with a short vent duct (maximum 10 m total length). The ring adapter is removable and de- signed for use with all venting systems.

**Note for test institutes: EN 61121 Standard testing is carried out with the ring adapter.

Venting system with Flexible ducting hose

This is a simple, cost effective method of directing the moist air out- side. The adapter supplied is fitted into the vent opening on the dryer and the ducting hose is then con- nected to the adapter.

^The following items are required: . .

. . . flexible ducting hose*

. . . a wall vent kit* or window vent kit*.

*(Miele optional accessory)

ARing adapter (1) must be taken out of adapter (2), if the total duct length is longer than 10 m.

If the total duct length is less than 10 m the ring adapter (1) should be left in adapter (2).

BFit adapter (2) into the vent opening on the dryer, and connect vent hose

(3).