Calculation example
A Wallpipe, with louvred vent
=1 x 3.8 m Additional duct
length
=3.8 m
B/D 2Elbows, 90°
=2 x 0.8 m Additional duct
length
=1.6 m
C 0.5m plastic piping
=0.5x1mAdditionalduct
length
=0.5 m
E Side connection, left
=1 m Additional duct length =1.0 m
Totalduct length =6.9 m
Result: A duct diameter of 100 mm is
adequate as the total duct length is less
than the 20 m specified in Table II.
Installation to the rear, left orright side of the appliance
At the rear
The dryer is delivered with this
connection open.
^Fit one of the venting systems
described on the following pages.
Left or right side of the appliance
^Turn the cover flap anti-clockwise.
^Refit it securely in the rear outlet.
^Fit one of the venting systems
described on the following pages.
Installation - venting
42